PPP-NCLPt datasheet

manufacturer:
www.nanosensors.com
View this AFM Tip
on manufacturer's website

AFM Probe Type: PPP-NCLPt

Product Description:
The new PointProbe® Plus (PPP) combines the well-known features of the proven PointProbe® series such as high application versatility and compatibility with most commercial SPMs with a more reproducible tip radius as well as a more defined tip shape. The minimized variation in tip shape provides more reproducible images.

NANOSENSORS PPP-NCL probes are designed for non-contact mode or tapping mode AFM (also known as: attractive or dynamic mode). As an alternative to NANOSENSORS high frequency non contact type (NCH) the NCL type is offered. This type is recommended if the feedback loop of the microscope does not accept high frequencies (400 kHz) or if the detection system needs a minimum cantilever length > 125 µm. Compared to the high frequency non-contact type NCH the maximum scanning speed is slightly reduced. This sensor type combines high operation stability with outstanding sensitivity and fast scanning ability.

 
    The probe offers unique features:
        - metallic conductivity
        - high mechanical Q-factor for high sensitivity
        - precise alignment of the cantilever position (within +/- 2 µm) in conjunction with the usage
          of the alignment chip
        - compatible with PointProbe® Plus XY-Alignment Series

 

This product features alignment grooves on the backside of the holder chip.

AFM Probe Specifications:
  AFM Cantilevers:
Cant. LengthWidthThicknessForce Const.Res. Freq.
1 225 µm(215 - 235 µm)* 38 µm(30 - 45 µm)* 7 µm(6 - 8 µm)* 48 N/m(21 - 98 N/m)* 190 kHz(146 - 236 kHz)*
  AFM Tips:
on Cant. Shape
1 Standard

* - guaranteed range

Coating:
The PtIr5 coating is an approximately 25 nm thick double layer of chromium and platinum iridium5 on both sides of the cantilever. The tip side coating enhances the conductivity of the tip and allows electrical contacts. The detector side coating enhances the reflectivity of the laser beam by a factor of about 2 and prevents light from interfering within the cantilever. The coating process is optimized for stress compensation and wear resistance. The bending of the cantilever due to stress is less than 3.5% of the cantilever length. Please note: Wear at the tip can occur if operating in contact-, friction- or force modulation mode.
Sensors Datasheets:

Datasheet for all AFM probes with sets of 10 or 20 probes.
Datasheet for up to 32 probes with full wafer.

Purchasing Info:

Product Availability:
From stock
Price Description:

No taxes applied except 5% in South Carolina.
Does not include overnight, 2nd or 3rd day shipping.

Order:
Order Code Sensors per Set price, USD Quantity
PPP-NCLPt-10
10 pcs 449.00 add to shopping cart
PPP-NCLPt-20
20 pcs 803.00 add to shopping cart
PPP-NCLPt-50
50 pcs 1771.00 add to shopping cart
PPP-NCLPt-W
385 pcs 8973.00 add to shopping cart
 
 
adding product
to shopping cart...
NanoAndMore USA Online Shop
Online Payments:
We accept VISA, MasterCard and American Express credit cards.
Customer Support:
CALL US NOW: 877-521-1108!
Toll free number for the US and Canada.

E-mail us:
Shopping Info:
NanoAndMore USA ©2007              Member of NanoWorld Group