Standard Non-Rotated AFM Tips

AFM probes with standard non-rotated 4-sided pyramidal macroscopic shape of the AFM tips
Sort by:
123 results
AR5-NCLR
AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NW-AR5-NCLR
NW-AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long Cantilever
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
CDT-NCHR
CDT-NCHR
Diamond Coated, Conductive Tapping Mode AFM Probe
Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
CDT-NCLR
CDT-NCLR
Diamond Coated, Conductive Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm
NW-CDT-NCHR
NW-CDT-NCHR

Diamond Coated, Conductive Tapping Mode AFM Probe

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
NW-CDT-NCLR
NW-CDT-NCLR

Diamond Coated, Conductive Tapping Mode AFM Probe with Long Cantilever

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm
PPP-NCHPt
PPP-NCHPt
Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-NCSTPt
PPP-NCSTPt
Electrical, Soft Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-NCLPt
PPP-NCLPt
Electrical, Tapping Mode AFM Probe with a Long AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCHPt
NCHPt
Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
NCLPt
NCLPt
Electrical, Tapping Mode AFM Probe with a Long Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
PPP-CONTPt
PPP-CONTPt
Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
PPP-CONTSCPt
PPP-CONTSCPt
Electrical, Contact Mode AFM Probe with Short AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
CONTPt
CONTPt
Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
SCM-PIC
SCM-PIC
Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
SCM-PIT
SCM-PIT
Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
PPP-FMAu
PPP-FMAu
Gold Coated Force Modulation AFM Probe
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
EBD-HAR
EBD-HAR
Universal high-aspect ratio EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
EBD-AR20T
EBD-AR20T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
PPP-CONTAu
PPP-CONTAu
Gold Coated Contact Mode AFM Probe
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
7