PPP-NCLR

Tapping Mode AFM Probe, Long Cantilever

Coating: Reflex Aluminum
Tip shape: Standard
Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
*nominal values

The new PointProbe® Plus (PPP) combines the well-known features of the proven PointProbe® series such as high application versatility and compatibility with most commercial SPMs with a further reduced and more reproducible tip radius as well as a more defined tip shape. The excellent tip radius and the minimized variation in tip shape provide more reproducible images and enhanced resolution.

NANOSENSORS™ PPP-NCLR AFM probes are designed for non-contact mode or tapping mode AFM (also known as: attractive or dynamic mode). The NCL type is offered as an alternative to NANOSENSORS™ high frequency non contact type (NCH). PPP-NCLR is recommended if the feedback loop of the microscope does not accept high frequencies (400 kHz) or if the detection system needs a minimum cantilever length > 125 µm. Compared to the high frequency non-contact type NCH the maximum scanning speed is slightly reduced. This probe type combines high operation stability with outstanding sensitivity and fast scanning ability.
 
The probe offers unique features:

  • excellent tip radius of curvature
  • highly doped silicon to dissipate static charge
  • Al coating on detector side of cantilever
  • high mechanical Q-factor for high sensitivity
  • precise alignment of the cantilever position (within +/- 2 µm) when used with the Alignment Chip
  • compatible with PointProbe® Plus XY-Alignment Series
The reflex coating is an approximately 30 nm thick aluminum coating on the detector side of the cantilever which enhances the reflectivity of the laser beam by a factor of about 2.5. Furthermore it prevents light from interfering within the cantilever. The virtually stress-free coating is bending the cantilever less than 2% of the cantilever length.

AFM Tip:

  • AFM Cantilever:

  • Beam
  • 225 µm (215 - 235 µm)*
  • 38 µm (30 - 45 µm)*
  • 7 µm (6 - 8 µm)*
  • 48 N/m (21 - 98 N/m)*
  • 190 kHz (146 - 236 kHz)*
  • * guaranteed range This product features alignment grooves on the back side of the holder chip.