AFM Probes » NW-AR5-NCLR

 Order  Request a quote (RFQ)
Order Code Price
Quantity
NW-AR5-NCLR-10 Box of 10 AFM Probes
$839.00
NW-AR5-NCLR-20 Box of 20 AFM Probes
$1 502.00
You save 176.00 USD or 10.50% with this box
NW-AR5-NCLR-50 Box of 50 AFM Probes
$3 314.00
You save 881.00 USD or 21.00% with this box
NW-AR5-NCLR-380 Box of 380 AFM Probes
$16 795.00
You save 15087.00 USD or 47.30% with this box
esd kit

ESD Kit recommended with this product. Click here to order: ESD Kit

NW-AR5-NCLR

High-Aspect-Ratio, Tapping Mode AFM Probe with Long Cantilever

Coating: Reflex Aluminum
Tip shape: High-Aspect-Ratio
Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
*nominal values
NanoWorld Pointprobe® NCL probes are designed for non-contact or tapping mode imaging and offer an alternative to our high frequency non-contact type NCH. The NCL type is recommended if the feedback loop of the microscope does not accept high frequencies or if the detection system needs a minimum cantilever length (> 125 µm). This probe combines high operation stability with outstanding sensitivity. Compared to the high frequency non-contact type NCH the maximum scanning speed is slightly reduced.

All SPM and AFM probes of the Pointprobe® series are made from monolithic silicon which is highly doped to dissipate static charge. They are chemically inert and offer a high mechanical Q-factor for high sensitivity. The tip is shaped like a polygon based pyramid.

For measurements on samples with sidewall angles approaching 90° we offer specially tailored tips showing a high aspect ratio portion with near-vertical sidewalls.

These probes offer unique features:

  • length of the high aspect ratio portion of the tip > 2 µm
  • typical aspect ratio of this portion in the order of 7:1 (when viewed from side as well as along cantilever axis)
  • half cone angle of the high aspect ratio portion typically < 5°
  • excellent tip radius of curvature
Aluminum Reflex Coating

The aluminum reflex coating consists of a 30 nm thick aluminum layer deposited on the detector side of the cantilever which enhances the reflectance of the laser beam by a factor of 2.5. Furthermore it prevents light from interfering within the cantilever.

AFM Tip:

  • AFM Cantilever:

  • Beam
  • 225 µm (220 - 230 µm)*
  • 38 µm (33 - 43 µm)*
  • 7 µm (6.5 - 7.5 µm)*
  • 48 N/m (31 - 71 N/m)*
  • 190 kHz (160 - 210 kHz)*
  • * typical range This product features alignment grooves on the back side of the holder chip.

    Give us your feedback

    Did we miss any relevant information of this product?
    Did you find this or a comparable product for a better price?