Search Results

78 results matching your criteria
the industry standard
NCHR

NCHR

Standard Tapping Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 320 kHz
C 42 N/m
L 125 µm
TESPA

TESPA

Standard Tapping Mode AFM Probe

Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 320 kHz
C 42 N/m
L 125 µm
ARROW-NCR

ARROW-NCR

Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: Arrow
Cantilever:
F 285 kHz
C 42 N/m
L 160 µm
NCLR

NCLR

Tapping Mode AFM Probe, Long Cantilever
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
the industry standard
NCSTR

NCSTR

Soft Tapping Mode AFM Probe

Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 160 kHz
C 7.4 N/m
L 150 µm
ARROW-FMR

ARROW-FMR

Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: Arrow
Cantilever:
F 75 kHz
C 2.8 N/m
L 240 µm
the industry standard
FMR

FMR

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
the industry standard
NW-SSS-NCH

NW-SSS-NCH

SuperSharp, Tapping Mode AFM Probe
Coating: none
Tip Shape: Supersharp
Cantilever:
F 320 kHz
C 42 N/m
L 125 µm
TESP-SS

TESP-SS

SuperSharp, Tapping Mode AFM Probe

Coating: none
Tip Shape: Supersharp
Cantilever:
F 320 kHz
C 42 N/m
L 125 µm
the industry standard
NW-DT-NCHR

NW-DT-NCHR

Diamond Coated Tapping Mode AFM Probe
Coating: Diamond
Tip Shape: Standard
Cantilever:
F 400 kHz
C 80 N/m
L 125 µm
NW-DT-FMR

NW-DT-FMR

Diamond Coated Force Modulation AFM Probe
Coating: Diamond
Tip Shape: Standard
Cantilever:
F 105 kHz
C 6.2 N/m
L 225 µm
NW-DT-NCLR

NW-DT-NCLR

Diamond Coated Tapping Mode AFM Probe with Long Cantilever
Coating: Diamond
Tip Shape: Standard
Cantilever:
F 210 kHz
C 72 N/m
L 225 µm
the industry standard
CONTR

CONTR

Standard Contact Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
ARROW-CONTR

ARROW-CONTR

Contact Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: Arrow
Cantilever:
F 14 kHz
C 0.2 N/m
L 450 µm
the industry standard
NW-CDT-FMR

NW-CDT-FMR

Diamond Coated, Conductive Force Modulation AFM Probe

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
Cantilever:
F 105 kHz
C 6.2 N/m
L 225 µm
ARROW-EFM

ARROW-EFM

Electrical, Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
Cantilever:
F 75 kHz
C 2.8 N/m
L 240 µm
the industry standard
EFM

EFM

Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
DDESP-FM

DDESP-FM

Diamond Coated, Conductive Force Modulation AFM Probe

Coating: Diamond
Tip Shape: Standard
Cantilever:
F 105 kHz
C 6.2 N/m
L 225 µm
DDESP

DDESP

Diamond Coated, Conductive Tapping Mode AFM Probe

Coating: Diamond
Tip Shape: Standard
Cantilever:
F 400 kHz
C 80 N/m
L 125 µm
ARROW-UHFAuD

ARROW-UHFAuD

Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever

Coating: Reflex Gold
Tip Shape: Arrow
Cantilever:
F 2000 kHz
L 35 µm
4