Search Results

49 results matching your criteria
EBD-NCH

EBD-NCH

Universal EBD whisker for enhanced resolution, imaging stability and tip lifetime
Coating: none
Tip Shape: Cone Shaped,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
biotool cell

biotool cell

EBD carbon whisker with 25 nm radius on soft cantilever
Coating: Reflex (Au)
Tip Shape: Cone Shaped,EBD
Cantilever:
F 50 kHz
C 0.1 N/m
L 60 µm
biotool high resolution

biotool high resolution

EBD carbon whisker with 2 nm radius on soft cantilever
Coating: none
Tip Shape: none
Cantilever:
F 50 kHz
C 0.1 N/m
L 60 µm
biotool cell XXL

biotool cell XXL

Extralong 15 um EBD carbon whisker with 25 nm radius on soft cantilever
Coating: none
Tip Shape: none
Cantilever:
F 50 kHz
C 0.1 N/m
L 60 µm
SuperSharp Enhanced

SuperSharp Enhanced

Ultrasharp EBD AFM whisker for high-resolution, non-contact AFM
Coating: Reflex Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Cantilever:
F 320 kHz
C 40 N/m
L 120 µm
SuperSharpStandard-NCH

SuperSharpStandard-NCH

SuperSharp diamond-like EBD whisker for non-contact AFM
Coating: Reflex Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
SuperSharp Enhanced-soft

SuperSharp Enhanced-soft

Ultrasharp EBD AFM whisker for high-resolution, soft tapping AFM
Coating: Reflex Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
EBD-AR15T

EBD-AR15T

High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
M-CIS

M-CIS

EBD AFM whisker for non-contact AFM microlens contact image sensor (CIS) inspection
Coating: Reflex Aluminum
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
Cantilever:
F 320 kHz
C 40 N/m
L 120 µm
EBD-HAR

EBD-HAR

Universal high-aspect ratio EBD whisker for enhanced resolution, imaging stability and tip lifetime
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
EBD-AR20T

EBD-AR20T

High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
M1-HAR

M1-HAR

High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
Cantilever:
F 320 kHz
C 40 N/m
L 120 µm
SuperSharpStandard-FM

SuperSharpStandard-FM

SuperSharp diamond-like EBD whisker for soft tapping AFM
Coating: Reflex Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B20-NCH

biosphere B20-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex (Au)
Tip Shape: Sphere,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B20-FM

biosphere B20-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex (Au)
Tip Shape: Sphere,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B20-CONT

biosphere B20-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex (Au)
Tip Shape: Sphere,EBD
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
New
biosphere B30-NCH

biosphere B30-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex (Au)
Tip Shape: Sphere,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B30-FM

biosphere B30-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex (Au)
Tip Shape: Sphere,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B30-CONT

biosphere B30-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex (Au)
Tip Shape: Sphere,EBD
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
New
biosphere B40-NCH

biosphere B40-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex (Au)
Tip Shape: Sphere,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
3