Search Results

52 results matching your criteria
New
55AC-NN

55AC-NN

Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever

Coating: none
Tip Shape: OPUS
Cantilever:
F 1200 kHz
C 85 N/m
L 65 µm
New
55AC-NG

55AC-NG

Gold Coated Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever

Coating: Reflex Gold
Tip Shape: OPUS
Cantilever:
F 1200 kHz
C 85 N/m
L 65 µm
New
3XC-NN

3XC-NN

AFM Probe with 3 Different Cantilevers for Various Applications and  Tips at the Very End of the Cantilevers
Coating: none
Tip Shape: OPUS
Cantilevers: 3
F 17 kHz
C 0.3 N/m
L 500 µm
F 150 kHz
C 9 N/m
L 175 µm
F 75 kHz
C 2.5 N/m
L 240 µm
New
HQ:CSC17/Cr-Au BS

HQ:CSC17/Cr-Au BS

Gold Coated Contact Mode AFM Probe
Coating: Reflex Gold
Tip Shape: Rotated
Cantilever:
F 13 kHz
C 0.18 N/m
L 450 µm
Mix and Match Box

Mix and Match Box

Mixed box: up to 400 MikroMasch AFM probes
Coating: various
Tip Shape: various
New
3XC-GG

3XC-GG

AFM Probe with 3 Different Gold Coated Cantilevers for Various Applications and Tips at the Very End of the Cantilevers
Coating: Gold Overall
Tip Shape: OPUS
Cantilevers: 3
F 17 kHz
C 0.3 N/m
L 500 µm
F 150 kHz
C 9 N/m
L 175 µm
F 75 kHz
C 2.5 N/m
L 240 µm
New
biosphere B20-NCH

biosphere B20-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B20-FM

biosphere B20-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B20-CONT

biosphere B20-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
New
biosphere B30-NCH

biosphere B30-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B30-FM

biosphere B30-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B30-CONT

biosphere B30-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
New
biosphere B40-NCH

biosphere B40-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B40-FM

biosphere B40-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B40-CONT

biosphere B40-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
New
biosphere B50-NCH

biosphere B50-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B50-FM

biosphere B50-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B50-CONT

biosphere B50-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
New
biosphere B100-NCH

biosphere B100-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B100-FM

biosphere B100-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
3