AFM Probe Type: SSS-NCLR

Product Description:

NANOSENSORS™ SSS-NCLR probes are designed for non-contact mode or tapping mode AFM. They are offered as an alternative to the NANOSENSORS™ high frequency non contact type (NCH). The SSS-NCLR is recommended if the feedback loop of the microscope does not accept high frequencies (400 kHz) or if the detection system needs a minimum cantilever length > 125 µm. Compared to the high frequency non-contact type NCH the maximum scanning speed is slightly reduced. This AFM probe combines high operation stability with outstanding sensitivity and fast scanning ability.

For enhanced resolution of nanostructures and microroughness we offer our SuperSharpSilicon™ tip with unrivalled sharpness.

 
    The probe offers unique features:
        - excellent tip radius of curvature
        - typical aspect ratio at 200 nm from tip apex in the order of 4:1
        - highly doped to dissipate static charge
        - high mechanical Q-factor for high sensitivity
        - precise alignment of the cantilever position (within +/- 2 µm) in conjunction with the usage
          of the alignment chip
        - compatible with PointProbe® Plus XY-Alignment Series

 

This product features alignment grooves on the backside of the holder chip.

AFM Probe Specifications:
  AFM Cantilevers:
Cant. LengthWidthThicknessForce Const.Res. Freq.
1 225 µm(215 - 235 µm)* 38 µm(30 - 45 µm)* 7 µm(6 - 8 µm)* 48 N/m(21 - 98 N/m)* 190 kHz(146 - 236 kHz)*
  AFM Tips:
on Cant. ShapeTip RadiusHalf Cone Angles
1 Supersharp <2 nm( < 5 nm guaranteed ) < 10° at 200 nm from apex

* guaranteed range

Coating:

The reflex coating is an approximately 30 nm thick aluminum coating on the detector side of the cantilever which enhances the reflectivity of the laser beam by a factor of about 2.5. Furthermore it prevents light from interfering within the cantilever. The virtually stress-free coating is bending the cantilever less than 2% of the cantilever length.

Sensors Datasheets:

Datasheet for all AFM probes with sets of 10 or 20 probes.
Datasheet for up to 32 probes with full wafer.

Purchasing Info:

Product Availability:
From stock
Price Description:

Does not include VAT or customs duties.

Order:
Order Code Sensors per Set price, EUR Quantity
SSS-NCLR-10
10 pcs 653.00 add to shopping cart
SSS-NCLR-20
20 pcs 1169.00 add to shopping cart
SSS-NCLR-50
50 pcs 2576.00 add to shopping cart
SSS-NCLR-W
385 pcs 12708.00 add to shopping cart