| type |
manufacturer |
short description |
short specs: |
tip shape |
PPP-NCH |
 |
Standard Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Standard |
PPP-NCHR |
 |
Standard Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Standard |
NCH |
 |
Standard Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 320 kHz
|
Standard |
NCHR |
 |
Standard Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 320 kHz
|
Standard |
TESP |
 |
Standard Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 320 kHz
|
Standard |
TESPA |
 |
Standard Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 320 kHz
|
Standard |
Tap300 |
 |
Standard Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 125 µm force const.: 40 N/m res. freq.: 300 kHz
|
Rotated |
Tap300Al |
 |
Standard Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 40 N/m res. freq.: 300 kHz
|
Rotated |
PPP-NCL |
 |
Tapping Mode AFM Probe, Long Cantilever |
coating:None AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Standard |
PPP-NCLR |
 |
Tapping Mode AFM Probe, Long Cantilever |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Standard |
NCL |
 |
Tapping Mode AFM Probe, Long Cantilever |
coating:None AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Standard |
NCLR |
 |
Tapping Mode AFM Probe, Long Cantilever |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Standard |
LTESP |
 |
Tapping Mode AFM Probe, Long Cantilever |
coating:None AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Standard |
Tap190-G |
 |
Tapping Mode AFM Probe, Long Cantilever |
coating:None AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Rotated |
 Tap190Al-G |
 |
Tapping Mode AFM Probe, Long Cantilever |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Rotated |
 PPP-NCST |
 |
Soft Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 150 µm force const.: 7.4 N/m res. freq.: 160 kHz
|
Standard |
 PPP-NCSTR |
 |
Soft Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 150 µm force const.: 7.4 N/m res. freq.: 160 kHz
|
Standard |
 NCST |
 |
Soft Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 150 µm force const.: 7.4 N/m res. freq.: 160 kHz
|
Standard |
 NCSTR |
 |
Soft Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 150 µm force const.: 7.4 N/m res. freq.: 160 kHz
|
Standard |
Tap150-G |
 |
Soft Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 125 µm force const.: 5 N/m res. freq.: 150 kHz
|
Rotated |
Tap150Al-G |
 |
Soft Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 5 N/m res. freq.: 150 kHz
|
Rotated |
ATEC-NC |
 |
Tapping Mode AFM Probe with a REAL Visible Tip |
coating:None AFM cantilever: length: 160 µm force const.: 45 N/m res. freq.: 335 kHz
|
Visible |
ARROW-NC |
 |
Tapping Mode AFM Probe with Tip at the Very End of the Cantilever |
coating:None AFM cantilever: length: 160 µm force const.: 42 N/m res. freq.: 285 kHz
|
Arrow |
ARROW-NCR |
 |
Tapping Mode AFM Probe with Tip at the Very End of the Cantilever |
coating:Reflex Aluminum AFM cantilever: length: 160 µm force const.: 42 N/m res. freq.: 285 kHz
|
Arrow |
 ARROW-UHF |
 |
Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever |
coating:Reflex Aluminum AFM cantilever: length: 35 µm force const.: - res. freq.: 1.5 kHz
|
Arrow |
SSS-NCH |
 |
SuperSharp, Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Supersharp |
SSS-NCHR |
 |
SuperSharp, Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Supersharp |
SSS-NCLR |
 |
SuperSharp, Tapping Mode AFM Probe with Long Cantilever |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Supersharp |
SSS-NCL |
 |
SuperSharp, Tapping Mode AFM Probe with Long Cantilever |
coating:None AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Supersharp |
TESP-SS |
 |
SuperSharp, Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 320 kHz
|
Supersharp |
NW-SSS-NCH |
 |
SuperSharp, Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Supersharp |
NW-SSS-NCL |
 |
SuperSharp, Tapping Mode AFM Probe with Long Cantilever |
coating:None AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Supersharp |
PPP-XYNCHR |
 |
Tapping Mode AFM Probe with Special Alignment System |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Standard |
 PPP-XYNCSTR |
 |
Soft Tapping Mode AFM Probe with Special Alignment System |
coating:Reflex Aluminum AFM cantilever: length: 150 µm force const.: 7.4 N/m res. freq.: 160 kHz
|
Standard |
PPP-QNCHR |
 |
Tapping Mode AFM Probe, for UHV Conditions |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Standard |
PPP-NCVH |
 |
Tapping Mode AFM Probe with a High Mechanical Q-Factor |
coating:None AFM cantilever: length: 50 µm force const.: 140 N/m res. freq.: 1100 kHz
|
Standard |
 PPP-NCHAuD |
 |
Gold Coated Tapping Mode AFM Probe |
coating:Reflex Gold AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Standard |
 PPP-NCLAuD |
 |
Gold Coated Tapping Mode AFM Probe with Long Cantilever |
coating:Reflex Gold AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Standard |
 PPP-NCSTAuD |
 |
Gold Coated Soft Tapping Mode AFM Probe |
coating:Reflex Gold AFM cantilever: length: 150 µm force const.: 7.4 N/m res. freq.: 160 kHz
|
Standard |
Tap300GD |
 |
Gold Coated Tapping Mode AFM Probe |
coating:Reflex Gold AFM cantilever: length: 125 µm force const.: 40 N/m res. freq.: 300 kHz
|
Rotated |
BudgetComboBox |
 |
Mixed Box with 50 BudgetSensors AFM probes of your choice |
|
|
 PL2-NCH |
 |
Tapping Mode AFM Probe with Plateau Tip |
coating:None AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Plateau |
 PL2-NCHR |
 |
Tapping Mode AFM Probe with Plateau Tip |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Plateau |
 PL2-NCL |
 |
Tapping Mode AFM Probe with Long Cantilever and Plateau Tip |
coating:None AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Plateau |
 PL2-NCLR |
 |
Tapping Mode AFM Probe with Long Cantilever and Plateau Tip |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Plateau |
PPP-SEIH |
 |
Special Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 225 µm force const.: 15 N/m res. freq.: 130 kHz
|
Standard |
PPP-SEIHR |
 |
Special Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 15 N/m res. freq.: 130 kHz
|
Standard |
SEIHR |
 |
Special Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 15 N/m res. freq.: 130 kHz
|
Standard |
SSS-SEIH |
 |
SuperSharp, Special Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 225 µm force const.: 15 N/m res. freq.: 130 kHz
|
Supersharp |
SSS-SEIHR |
 |
SuperSharp, Special Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 15 N/m res. freq.: 130 kHz
|
Supersharp |
NW-SSS-SEIH |
 |
SuperSharp, Special Tapping Mode AFM Probe |
coating:None AFM cantilever: length: 225 µm force const.: 15 N/m res. freq.: 130 kHz
|
Supersharp |
PPP-ZEIHR |
 |
Special Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 27 N/m res. freq.: 130 kHz
|
Standard |
ZEIHR |
 |
Special Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 27 N/m res. freq.: 130 kHz
|
Standard |
PPP-ZEIHRR |
 |
Special Tapping Mode AFM Probe |
coating:Reflex Double Aluminum AFM cantilever: length: 225 µm force const.: 27 N/m res. freq.: 130 kHz
|
Standard |
PPP-ZEILR |
 |
Special Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 450 µm force const.: 1.6 N/m res. freq.: 27 kHz
|
Standard |
PPP-ZEILRR |
 |
Special Contact Mode AFM Probe |
coating:Reflex Double Aluminum AFM cantilever: length: 450 µm force const.: 1.6 N/m res. freq.: 27 kHz
|
Standard |
ZEILR |
 |
Special Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 450 µm force const.: 1.6 N/m res. freq.: 27 kHz
|
Standard |
PPP-RT-NCHR |
 |
Standard Tapping Mode AFM Probe |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Rotated |