AFM probes, tips, cantilevers

 
 
adding product
to shopping cart...
advanced search

» Non-Contact / Tapping Mode AFM Probes:

type manufacturer short description short specs: tip shape
PPP-NCH PPP-NCH NANOSENSORS Standard Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Standard
PPP-NCHR PPP-NCHR NANOSENSORS Standard Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Standard
NCH NCH NanoWorld Standard Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 320 kHz
Standard
NCHR NCHR NanoWorld Standard Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 320 kHz
Standard
TESP TESP NanoWorld Standard Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 320 kHz
Standard
TESPA TESPA NanoWorld Standard Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 320 kHz
Standard
Tap300 Tap300 BudgetSensors Standard Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 125 µm
  force const.: 40 N/m
  res. freq.: 300 kHz
Rotated
Tap300Al Tap300Al BudgetSensors Standard Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 40 N/m
  res. freq.: 300 kHz
Rotated
PPP-NCL PPP-NCL NANOSENSORS Tapping Mode AFM Probe, Long Cantilever coating:None
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Standard
PPP-NCLR PPP-NCLR NANOSENSORS Tapping Mode AFM Probe, Long Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Standard
NCL NCL NanoWorld Tapping Mode AFM Probe, Long Cantilever coating:None
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Standard
NCLR NCLR NanoWorld Tapping Mode AFM Probe, Long Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Standard
LTESP LTESP NanoWorld Tapping Mode AFM Probe, Long Cantilever coating:None
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Standard
Tap190-G Tap190-G BudgetSensors Tapping Mode AFM Probe, Long Cantilever coating:None
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Rotated
Tap190Al-G Tap190Al-G BudgetSensors Tapping Mode AFM Probe, Long Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Rotated
PPP-NCST PPP-NCST NANOSENSORS Soft Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 150 µm
  force const.: 7.4 N/m
  res. freq.: 160 kHz
Standard
PPP-NCSTR PPP-NCSTR NANOSENSORS Soft Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 150 µm
  force const.: 7.4 N/m
  res. freq.: 160 kHz
Standard
NCST NCST NanoWorld Soft Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 150 µm
  force const.: 7.4 N/m
  res. freq.: 160 kHz
Standard
NCSTR NCSTR NanoWorld Soft Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 150 µm
  force const.: 7.4 N/m
  res. freq.: 160 kHz
Standard
Tap150-G Tap150-G BudgetSensors Soft Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 125 µm
  force const.: 5 N/m
  res. freq.: 150 kHz
Rotated
Tap150Al-G Tap150Al-G BudgetSensors Soft Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 5 N/m
  res. freq.: 150 kHz
Rotated
ATEC-NC ATEC-NC NANOSENSORS Tapping Mode AFM Probe with a REAL Visible Tip coating:None
AFM cantilever:
  length: 160 µm
  force const.: 45 N/m
  res. freq.: 335 kHz
Visible
ARROW-NC ARROW-NC NanoWorld Tapping Mode AFM Probe with Tip at the Very End of the Cantilever coating:None
AFM cantilever:
  length: 160 µm
  force const.: 42 N/m
  res. freq.: 285 kHz
Arrow
ARROW-NCR ARROW-NCR NanoWorld Tapping Mode AFM Probe with Tip at the Very End of the Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 160 µm
  force const.: 42 N/m
  res. freq.: 285 kHz
Arrow
ARROW-UHF ARROW-UHF NanoWorld Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 35 µm
  force const.: -
  res. freq.: 1.5 kHz
Arrow
SSS-NCH SSS-NCH NANOSENSORS SuperSharp, Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Supersharp
SSS-NCHR SSS-NCHR NANOSENSORS SuperSharp, Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Supersharp
SSS-NCLR SSS-NCLR NANOSENSORS SuperSharp, Tapping Mode AFM Probe with Long Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Supersharp
SSS-NCL SSS-NCL NANOSENSORS SuperSharp, Tapping Mode AFM Probe with Long Cantilever coating:None
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Supersharp
TESP-SS TESP-SS NanoWorld SuperSharp, Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 320 kHz
Supersharp
NW-SSS-NCH NW-SSS-NCH NanoWorld SuperSharp, Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Supersharp
NW-SSS-NCL NW-SSS-NCL NanoWorld SuperSharp, Tapping Mode AFM Probe with Long Cantilever coating:None
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Supersharp
PPP-XYNCHR PPP-XYNCHR NANOSENSORS Tapping Mode AFM Probe with Special Alignment System coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Standard
PPP-XYNCSTR PPP-XYNCSTR NANOSENSORS Soft Tapping Mode AFM Probe with Special Alignment System coating:Reflex Aluminum
AFM cantilever:
  length: 150 µm
  force const.: 7.4 N/m
  res. freq.: 160 kHz
Standard
PPP-QNCHR PPP-QNCHR NANOSENSORS Tapping Mode AFM Probe, for UHV Conditions coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Standard
PPP-NCVH PPP-NCVH NANOSENSORS Tapping Mode AFM Probe with a High Mechanical Q-Factor coating:None
AFM cantilever:
  length: 50 µm
  force const.: 140 N/m
  res. freq.: 1100 kHz
Standard
PPP-NCHAuD PPP-NCHAuD NANOSENSORS Gold Coated Tapping Mode AFM Probe coating:Reflex Gold
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Standard
PPP-NCLAuD PPP-NCLAuD NANOSENSORS Gold Coated Tapping Mode AFM Probe with Long Cantilever coating:Reflex Gold
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Standard
PPP-NCSTAuD PPP-NCSTAuD NANOSENSORS Gold Coated Soft Tapping Mode AFM Probe coating:Reflex Gold
AFM cantilever:
  length: 150 µm
  force const.: 7.4 N/m
  res. freq.: 160 kHz
Standard
Tap300GD Tap300GD BudgetSensors Gold Coated Tapping Mode AFM Probe coating:Reflex Gold
AFM cantilever:
  length: 125 µm
  force const.: 40 N/m
  res. freq.: 300 kHz
Rotated
BudgetComboBox BudgetComboBox BudgetSensors Mixed Box with 50 BudgetSensors AFM probes of your choice
PL2-NCH PL2-NCH NANOSENSORS Tapping Mode AFM Probe with Plateau Tip coating:None
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Plateau
PL2-NCHR PL2-NCHR NANOSENSORS Tapping Mode AFM Probe with Plateau Tip coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Plateau
PL2-NCL PL2-NCL NANOSENSORS Tapping Mode AFM Probe with Long Cantilever and Plateau Tip coating:None
AFM cantilever:
  length: 225 µm
  force const.: 48 N/m
  res. freq.: 190 kHz
Plateau
PL2-NCLR PL2-NCLR NANOSENSORS Tapping Mode AFM Probe with Long Cantilever and Plateau Tip coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Plateau
PPP-SEIH PPP-SEIH NANOSENSORS Special Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 225 µm
  force const.: 15 N/m
  res. freq.: 130 kHz
Standard
PPP-SEIHR PPP-SEIHR NANOSENSORS Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 15 N/m
  res. freq.: 130 kHz
Standard
SEIHR SEIHR NanoWorld Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 15 N/m
  res. freq.: 130 kHz
Standard
SSS-SEIH SSS-SEIH NANOSENSORS SuperSharp, Special Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 225 µm
  force const.: 15 N/m
  res. freq.: 130 kHz
Supersharp
SSS-SEIHR SSS-SEIHR NANOSENSORS SuperSharp, Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 15 N/m
  res. freq.: 130 kHz
Supersharp
NW-SSS-SEIH NW-SSS-SEIH NanoWorld SuperSharp, Special Tapping Mode AFM Probe coating:None
AFM cantilever:
  length: 225 µm
  force const.: 15 N/m
  res. freq.: 130 kHz
Supersharp
PPP-ZEIHR PPP-ZEIHR NANOSENSORS Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 27 N/m
  res. freq.: 130 kHz
Standard
ZEIHR ZEIHR NanoWorld Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 27 N/m
  res. freq.: 130 kHz
Standard
PPP-ZEIHRR PPP-ZEIHRR NANOSENSORS Special Tapping Mode AFM Probe coating:Reflex Double Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 27 N/m
  res. freq.: 130 kHz
Standard
PPP-ZEILR PPP-ZEILR NANOSENSORS Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 1.6 N/m
  res. freq.: 27 kHz
Standard
PPP-ZEILRR PPP-ZEILRR NANOSENSORS Special Contact Mode AFM Probe coating:Reflex Double Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 1.6 N/m
  res. freq.: 27 kHz
Standard
ZEILR ZEILR NanoWorld Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 1.6 N/m
  res. freq.: 27 kHz
Standard
PPP-RT-NCHR PPP-RT-NCHR NANOSENSORS Standard Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 125 µm
  force const.: 42 N/m
  res. freq.: 330 kHz
Rotated
NanoAndMore ©2007              Member of NanoWorld Group