type manufacturer short description short specs: tip shape
NANOSENSORS Standard Contact Mode AFM Probe coating:None
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Standard
NANOSENSORS Standard Contact Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Standard
NanoWorld Standard Contact Mode AFM Probe coating:None
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Standard
ESP ESP
NanoWorld Standard Contact Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Standard
NanoWorld Standard Contact Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Standard
BudgetSensors Standard Contact Mode AFM Probe coating:None
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Rotated
BudgetSensors Standard Contact Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Rotated
BudgetSensors Standard Contact Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Rotated
NANOSENSORS Contact Mode AFM Probe with Short Cantilever coating:None
AFM cantilever:
  length: 225 µm
  force const.: 0.2 N/m
  res. freq.: 23 kHz
Standard
NANOSENSORS Contact Mode AFM Probe with Short Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 0.2 N/m
  res. freq.: 23 kHz
Standard
NanoWorld Contact Mode AFM Probe with Short Cantilever coating:None
AFM cantilever:
  length: 225 µm
  force const.: 0.2 N/m
  res. freq.: 23 kHz
Standard
NanoWorld Contact Mode AFM Probe with Short Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 225 µm
  force const.: 0.2 N/m
  res. freq.: 23 kHz
Standard
NANOSENSORS Contact Mode AFM Probe with a REAL Visible Tip coating:None
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 15 kHz
Visible
NanoWorld Contact Mode AFM Probe with Tip at the Very End of the Cantilever coating:None
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 14 kHz
Arrow
NanoWorld Contact Mode AFM Probe with Tip at the Very End of the Cantilever coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 14 kHz
Arrow
NanoWorld Silicon Nitride AFM Probe coating:Reflex Chromium/Gold
AFM cantilever:
  length: 200 µm
  force const.: 0.08 N/m
  res. freq.: 17 kHz
AFM cantilever:
  length: 100 µm
  force const.: 0.32 N/m
  res. freq.: 67 kHz
Pyramid
NanoWorld Silicon Nitride AFM Probe coating:Reflex Chromium/Gold
AFM cantilever:
  length: 200 µm
  force const.: 0.06 N/m
  res. freq.: 17 kHz
AFM cantilever:
  length: 100 µm
  force const.: 0.48 N/m
  res. freq.: 67 kHz
Pyramid
NANOSENSORS Gold Coated Contact Mode AFM Probe coating:Reflex Gold
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Standard
BudgetSensors Gold Coated Contact Mode AFM Probe coating:Reflex Gold
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Rotated
BudgetSensors  
Mixed Box with 50 BudgetSensors AFM probes of your choice
 

NANOSENSORS Gold Coated Contact Mode AFM Probe with Short Cantilever coating:Gold Overall
AFM cantilever:
  length: 225 µm
  force const.: 0.2 N/m
  res. freq.: 23 kHz
Standard
NANOSENSORS Contact Mode AFM Probe with Special Alignment System coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Standard
NANOSENSORS Contact Mode AFM Probe with Plateau Tip coating:None
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Plateau
NANOSENSORS Contact Mode AFM Probe with Plateau Tip coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Plateau
NANOSENSORS Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 1.6 N/m
  res. freq.: 27 kHz
Standard
NanoWorld Special Tapping Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 1.6 N/m
  res. freq.: 27 kHz
Standard
NANOSENSORS Special Contact Mode AFM Probe coating:Reflex Double Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 1.6 N/m
  res. freq.: 27 kHz
Standard
NANOSENSORS Standard Contact Mode AFM Probe coating:Reflex Aluminum
AFM cantilever:
  length: 450 µm
  force const.: 0.2 N/m
  res. freq.: 13 kHz
Rotated
NANOSENSORS Soft Contact AFM Probe for Biological Applications coating:None
AFM cantilever:
  length: 225 µm
  force const.: 0.1 N/m
  res. freq.: 28 kHz
Standard
NanoAndMore USA Online Shop