best of the best
![PPP-NCHR](/uploads/media/default/0001/01/thumb_78_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCHR
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
![ATEC-NC](/uploads/media/default/0001/02/thumb_1443_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
ATEC-NC
Tapping Mode AFM Probe with REAL Tip Visibility
Coating:
none
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
335 kHz
C
45 N/m
L
160 µm
New
![PPP-NCR](/uploads/media/default/0001/01/thumb_78_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCR
Standard Tapping Mode AFM Probe with AC160 mechanical properties
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
300 kHz
C
26 N/m
L
125 µm
the industry standard
![NCHR](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
NCHR
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
![TESPA](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
TESPA
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
![ARROW-NCR](/uploads/media/default/0001/01/thumb_525_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
ARROW-NCR
Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating:
Reflective Aluminum
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
top value
![HQ:NSC15/Al BS](/uploads/media/default/0001/07/thumb_6288_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC15/Al BS
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
top value
![160AC-NA](/uploads/media/default/0001/02/thumb_1581_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
160AC-NA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
![OMCL-AC160TS](/uploads/media/default/0001/07/thumb_6386_default_small_100_100.jpeg)
![OLYMPUS OLYMPUS](/img/logos/nanoandmore.jp_small.jpg)
OMCL-AC160TS
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
best bang for your buck
![Tap300Al-G](/uploads/media/default/0001/02/thumb_1672_default_small_100_100.png)
![BudgetSensors BudgetSensors](/img/logos/budgetsensors.com_small.jpg)
Tap300Al-G
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
![OTESPA](/uploads/media/default/0001/02/thumb_1581_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
OTESPA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
![PPP-NCLR](/uploads/media/default/0001/01/thumb_109_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCLR
Tapping Mode AFM Probe, Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
![NCLR](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
NCLR
Tapping Mode AFM Probe, Long Cantilever
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
![HQ:NSC16/Al BS](/uploads/media/default/0001/07/thumb_6296_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC16/Al BS
Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
![Tap190Al-G](/uploads/media/default/0001/02/thumb_1643_default_small_100_100.png)
![BudgetSensors BudgetSensors](/img/logos/budgetsensors.com_small.jpg)
Tap190Al-G
Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
![EBD-NCH](/uploads/media/default/0001/02/thumb_1601_default_small_100_100.png)
![nanotools nanotools](/img/logos/nanotools.com_small.jpg)
EBD-NCH
Universal EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating:
none
Tip Shape: Cone Shaped,EBD
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
best of the best
![PPP-QNCHR](/uploads/media/default/0001/01/thumb_78_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-QNCHR
Tapping Mode AFM Probe, for UHV Conditions
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
![PPP-RT-NCHR](/uploads/media/default/0001/01/thumb_118_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-RT-NCHR
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
best of the best
![PPP-NCSTR](/uploads/media/default/0001/01/thumb_109_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCSTR
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
the industry standard
![NCSTR](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
NCSTR
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm