Uncoated AFM Cantilevers

AFM cantilevers without a coating
Sort by:
84 results
Tap300-G
Tap300-G
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
ATEC-NC
ATEC-NC
Tapping Mode AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
AFM Cantilever:
F
335 kHz
C
45 N/m
L
160 µm
PPP-NCST
PPP-NCST
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
NCST
NCST
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
ATEC-FM
ATEC-FM
Force Modulation AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm
SSS-NCH
SSS-NCH
SuperSharp, Tapping Mode AFM Probe
Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard
NW-SSS-NCH
NW-SSS-NCH
SuperSharp, Tapping Mode AFM Probe
Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
TESP-SS
TESP-SS

SuperSharp, Tapping Mode AFM Probe

Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
DT-FMR
DT-FMR
Diamond Coated Force Modulation AFM Probe
Coating: Diamond
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
ATEC-CONT
ATEC-CONT
Contact Mode AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
AFM Cantilever:
F
15 kHz
C
0.2 N/m
L
450 µm
55AC-NN
55AC-NN

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
PPP-CONTSC
PPP-CONTSC
Contact Mode AFM Probe with Short AFM Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
PPP-NCH
PPP-NCH
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
TESP
TESP

Standard Tapping Mode AFM Probe

Coating: none
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
ARROW-NC
ARROW-NC
Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: none
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
LTESP
LTESP

Tapping Mode AFM Probe, Long Cantilever

Coating: none
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCL
NCL
Tapping Mode AFM Probe, Long Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
HQ:NSC15/No Al
HQ:NSC15/No Al
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
HQ:NSC16/No Al
HQ:NSC16/No Al
Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
160AC-NN
160AC-NN
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
5