NanoAndMore SEA does not ship to your country
3 AFM Cantilevers on One Side of the AFM Probe
AFM probes with three AFM cantilevers on one side of the holder chip
Sort by:
40 results
![HQ:NSC35/Al BS](/uploads/media/default/0001/07/thumb_6323_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC35/Al BS
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
![HQ:NSC35/Hard/Al BS](/uploads/media/default/0001/02/thumb_1121_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC35/Hard/Al BS
AFM Probe with 3 Different Long Scanning, DLC Hardened Tapping Mode AFM Cantilevers
Coating:
Hard Diamond-Like-Carbon
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
![HQ:NSC35/Pt](/uploads/media/default/0001/02/thumb_1171_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC35/Pt
AFM Probe with 3 Different Electrical, Tapping Mode AFM Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
best of the best
![qp-BioAC](/uploads/media/default/0001/02/thumb_1378_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
qp-BioAC
uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 3 different AFM cantilevers
Coating:
Reflective Gold
Tip Shape: Circular symmetric
Tip Shape: Circular symmetric
AFM Cantilevers: 3
1
2
3
F
90 kHz
50 kHz
30 kHz
C
0.3 N/m
0.1 N/m
0.06 N/m
L
40 µm
60 µm
80 µm
best of the best
![qp-fast](/uploads/media/default/0001/02/thumb_1368_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
qp-fast
uniqprobe™ for Soft/Standard/Fast Tapping/Dynamic AFM imaging
Coating:
Reflective Gold
Tip Shape: Circular symmetric
Tip Shape: Circular symmetric
AFM Cantilevers: 3
1
2
3
F
800 kHz
420 kHz
250 kHz
C
80 N/m
30 N/m
15 N/m
L
40 µm
60 µm
80 µm
New
![qp-BioAC-CI](/uploads/media/default/0001/02/thumb_1378_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
qp-BioAC-CI
uniqprobe™ BioAC with Rounded AFM Tips for Cell Imaging
Coating:
Reflective Gold
Tip Shape: Circular symmetric
Tip Shape: Circular symmetric
AFM Cantilevers: 3
1
2
3
F
90 kHz
50 kHz
30 kHz
C
0.3 N/m
0.1 N/m
0.06 N/m
L
40 µm
60 µm
80 µm
![HQ:NSC35/Cr-Au BS](/uploads/media/default/0001/02/thumb_1125_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC35/Cr-Au BS
AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating:
Reflective Gold
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
![HQ:NSC36/Cr-Au BS](/uploads/media/default/0001/02/thumb_1125_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC36/Cr-Au BS
AFM Probe with 3 Different Gold Coated Force Modulation Mode AFM Cantilevers
Coating:
Reflective Gold
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
![Mix and Match Box](/uploads/media/default/0001/02/thumb_1434_default_small_100_100.png)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
Mix and Match Box
Mixed box: up to 400 MikroMasch AFM probes
Coating:
various
Tip Shape: various
Tip Shape: various
![HQ:NSC36/Co-Cr/Al BS](/uploads/media/default/0001/07/thumb_6323_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC36/Co-Cr/Al BS
Hard Magnetic, Medium Momentum MFM AFM Probe with 3 Different AFM Cantilevers
Coating:
Magnetic
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
60 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
top value
![3XC-NA](/uploads/media/default/0001/02/thumb_1995_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
3XC-NA
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
![HQ:NSC36/Al BS](/uploads/media/default/0001/07/thumb_6323_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC36/Al BS
AFM Probe with 3 Different Force Modulation Mode AFM Cantilevers
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
![HQ:NSC35/No Al](/uploads/media/default/0001/07/thumb_6322_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC35/No Al
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
![HQ:NSC36/No Al](/uploads/media/default/0001/07/thumb_6322_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC36/No Al
AFM Probe with 3 Different Force Modulation Mode AFM Cantilevers
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
![3XC-NN](/uploads/media/default/0001/02/thumb_1995_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
3XC-NN
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
![HQ:NSC36/Hard/Al BS](/uploads/media/default/0001/02/thumb_1121_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC36/Hard/Al BS
AFM Probe with 3 Different Long Scanning, DLC Hardened Force Modulation Mode AFM Cantilevers
Coating:
Hard Diamond-Like-Carbon
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
![HQ:CSC37/Al BS](/uploads/media/default/0001/07/thumb_6335_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:CSC37/Al BS
AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
![HQ:CSC38/Al BS](/uploads/media/default/0001/07/thumb_6335_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:CSC38/Al BS
AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
![HQ:CSC37/No Al](/uploads/media/default/0001/07/thumb_6336_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:CSC37/No Al
AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
![HQ:CSC38/No Al](/uploads/media/default/0001/07/thumb_6336_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:CSC38/No Al
AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm