Sort by:
21 results
best of the best
AR10T-NCHR
AR10T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5T-NCHR
AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard
NW-AR5T-NCHR
NW-AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
TESPA-HAR
TESPA-HAR

High-Aspect-Ratio, Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
top value
160AC-FG
160AC-FG
High Aspect Ratio, Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
240AC-FG
240AC-FG
High Aspect Ratio, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
EBD-AR15T
EBD-AR15T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
AR10-NCHR
AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCHR
AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCH
AR5-NCH
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: none
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
NW-AR10-NCHR
NW-AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
NW-AR5-NCHR
NW-AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
AR5-NCLR
AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NW-AR5-NCLR
NW-AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long Cantilever
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
M-CIS
M-CIS
EBD AFM whisker for non-contact AFM microlens contact image sensor (CIS) inspection
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
EBD-HAR
EBD-HAR
Universal high-aspect ratio EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
EBD-AR20T
EBD-AR20T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
M1-HAR
M1-HAR
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
ISC-125C40-R
ISC-125C40-R
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
ISC-225C3_0-R
ISC-225C3_0-R
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
2