best of the best
![PPP-NCHR](/uploads/media/default/0001/01/thumb_78_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCHR
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
![PPP-NCR](/uploads/media/default/0001/01/thumb_78_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCR
Standard Tapping Mode AFM Probe with AC160 mechanical properties
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
300 kHz
C
26 N/m
L
125 µm
the industry standard
![NCHR](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
NCHR
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
![TESPA](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
TESPA
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
![PPP-NCLR](/uploads/media/default/0001/01/thumb_109_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCLR
Tapping Mode AFM Probe, Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
![NCLR](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
NCLR
Tapping Mode AFM Probe, Long Cantilever
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
![EBD-NCH](/uploads/media/default/0001/02/thumb_1601_default_small_100_100.png)
![nanotools nanotools](/img/logos/nanotools.com_small.jpg)
EBD-NCH
Universal EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating:
none
Tip Shape: Cone Shaped,EBD
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
best of the best
![PPP-QNCHR](/uploads/media/default/0001/01/thumb_78_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-QNCHR
Tapping Mode AFM Probe, for UHV Conditions
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
best of the best
![PPP-NCSTR](/uploads/media/default/0001/01/thumb_109_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCSTR
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
the industry standard
![NCSTR](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
NCSTR
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
![PPP-NCST](/uploads/media/default/0001/01/thumb_78_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-NCST
Soft Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
![NCST](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
NCST
Soft Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
best of the best
![PPP-FMR](/uploads/media/default/0001/01/thumb_78_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
PPP-FMR
Standard Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
the industry standard
![FMR](/uploads/media/default/0001/01/thumb_132_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
FMR
Standard Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
best of the best
![SSS-NCHR](/uploads/media/default/0001/01/thumb_54_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
SSS-NCHR
SuperSharp, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
![SSS-NCLR](/uploads/media/default/0001/01/thumb_54_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
SSS-NCLR
SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
![SSS-FMR](/uploads/media/default/0001/01/thumb_54_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
SSS-FMR
SuperSharp, Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
![SSS-NCH](/uploads/media/default/0001/01/thumb_54_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
SSS-NCH
SuperSharp, Tapping Mode AFM Probe
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard
![NW-SSS-NCH](/uploads/media/default/0001/01/thumb_145_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
NW-SSS-NCH
SuperSharp, Tapping Mode AFM Probe
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
![TESP-SS](/uploads/media/default/0001/01/thumb_145_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
TESP-SS
SuperSharp, Tapping Mode AFM Probe
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm