PeakForce Quantitative Nanomechanics AFM Probes

PeakForce Tapping® based quantitative nanomechanical measurements (QNM) of modulus, adhesion force, deformation, energy dissipation, etc.

In addition to the AFM probes listed below, you can also consider the NANOSENSORS™ Special Developments List AFM probes SD-R30-NCH (R=30nm) and SD-T7L100 (C=600N/m).

Sort by:
50 results
top value
HQ:NSC15/Al BS
HQ:NSC15/Al BS
Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
top value
160AC-NA
160AC-NA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
OMCL-AC160TS
OMCL-AC160TS
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
best bang for your buck
Tap300Al-G
Tap300Al-G
Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
best of the best
PPP-NCSTR
PPP-NCSTR
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
the industry standard
NCSTR
NCSTR

Soft Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
top value
HQ:NSC14/Al BS
HQ:NSC14/Al BS
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
HQ:NSC35/Al BS
HQ:NSC35/Al BS
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
200AC-NA
200AC-NA
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
135 kHz
C
9 N/m
L
200 µm
New
OMCL-AC200TS
OMCL-AC200TS
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
150 kHz
C
9 N/m
L
200 µm
best bang for your buck
Tap150Al-G
Tap150Al-G
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
PPP-NCST
PPP-NCST
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
NCST
NCST
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
top value
240AC-NA
240AC-NA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
New
OMCL-AC240TS
OMCL-AC240TS
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best of the best
CDT-FMR
CDT-FMR
Diamond Coated, Conductive Force Modulation AFM Probe
Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
the industry standard
NW-CDT-FMR
NW-CDT-FMR

Diamond Coated, Conductive Force Modulation AFM Probe

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
best bang for your buck sale
All-In-One-DD
All-In-One-DD
Diamond Coated, Conductive AFM Probe with 4 Different AFM Cantilevers
Coating: Conductive Diamond
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
19 kHz
110 kHz
200 kHz
450 kHz
C
0.5 N/m
6.5 N/m
18 N/m
100 N/m
L
500 µm
210 µm
150 µm
100 µm
best of the best
qp-BioAC
qp-BioAC
uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 3 different AFM cantilevers
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 3
1
2
3
F
90 kHz
50 kHz
30 kHz
C
0.3 N/m
0.1 N/m
0.06 N/m
L
40 µm
60 µm
80 µm
The Standard SiNi probe
PNP-TR
PNP-TR
Silicon Nitride AFM Probe
Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
3