NanoAndMore GmbH does not ship to your country
Tipless AFM Cantilevers
Special AFM probes with tipless AFM cantilevers
Sort by:
29 results
best of the best
![TL-CONT](/uploads/media/default/0001/01/thumb_514_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
TL-CONT
Tipless Contact Mode AFM Cantilever
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
![TL-FM](/uploads/media/default/0001/01/thumb_514_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
TL-FM
Tipless Force Modulation AFM Cantilever
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
![TL-NCH](/uploads/media/default/0001/01/thumb_514_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
TL-NCH
Tipless Tapping Mode AFM Cantilever
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
![TL-NCL](/uploads/media/default/0001/01/thumb_514_default_small_100_100.jpeg)
![NANOSENSORS NANOSENSORS](/img/logos/nanosensors.com_small.jpg)
TL-NCL
Tipless, Long Tapping Mode AFM Cantilever
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
the industry standard
![ARROW-TL1](/uploads/media/default/0001/01/thumb_150_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
ARROW-TL1
Tipless AFM Cantilever for Special Applications
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
6 kHz
C
0.03 N/m
L
500 µm
![PNP-TR-TL](/uploads/media/default/0001/01/thumb_365_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
PNP-TR-TL
Tipless Silicon Nitride AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
![ARROW-TL2](/uploads/media/default/0001/01/thumb_151_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
ARROW-TL2
Tipless AFM Cantilever Array for Special Applications
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
F
6 kHz
C
0.03 N/m
L
500 µm
![ARROW-TL8](/uploads/media/default/0001/01/thumb_152_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
ARROW-TL8
Tipless AFM Cantilever Array for Special Applications
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 8
1
F
6 kHz
C
0.03 N/m
L
500 µm
![HQ:NSC35/tipless/No Al](/uploads/media/default/0001/07/thumb_6332_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC35/tipless/No Al
Tipless AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
![HQ:NSC36/tipless/No Al](/uploads/media/default/0001/07/thumb_6332_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC36/tipless/No Al
Tipless AFM Probe with 3 Different Force Modulation AFM Cantilevers
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
![HQ:CSC37/tipless/No Al](/uploads/media/default/0001/07/thumb_6338_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:CSC37/tipless/No Al
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
top value
![HQ:CSC38/tipless/No Al](/uploads/media/default/0001/07/thumb_6338_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:CSC38/tipless/No Al
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
best bang for your buck
![All-In-One-Tipless](/uploads/media/default/0001/02/thumb_1609_default_small_100_100.png)
![BudgetSensors BudgetSensors](/img/logos/budgetsensors.com_small.jpg)
All-In-One-Tipless
Tipless AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
![ARROW-TL1Au](/uploads/media/default/0001/01/thumb_150_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
ARROW-TL1Au
Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating:
Gold on Sample Facing Side
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
6 kHz
C
0.03 N/m
L
500 µm
![ARROW-TL2Au](/uploads/media/default/0001/01/thumb_151_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
ARROW-TL2Au
Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating:
Gold on Sample Facing Side
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
F
6 kHz
C
0.03 N/m
L
500 µm
![ARROW-TL8Au](/uploads/media/default/0001/01/thumb_152_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
ARROW-TL8Au
Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating:
Gold on Sample Facing Side
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 8
1
F
6 kHz
C
0.03 N/m
L
500 µm
![PNP-TR-TL-Au](/uploads/media/default/0001/01/thumb_366_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
PNP-TR-TL-Au
Tipless, Gold Coated Silicon Nitride AFM Cantilever
Coating:
Gold Overall
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
![HQ:NSC35/tipless/Cr-Au](/uploads/media/default/0001/07/thumb_6332_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC35/tipless/Cr-Au
Tipless AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
![Mix and Match Box](/uploads/media/default/0001/02/thumb_1434_default_small_100_100.png)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
Mix and Match Box
Mixed box: up to 400 MikroMasch AFM probes
Coating:
various
Tip Shape: various
Tip Shape: various
![HQ:NSC36/tipless/Cr-Au](/uploads/media/default/0001/07/thumb_6332_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
HQ:NSC36/tipless/Cr-Au
Tipless AFM Probe with 3 Different Gold Coated Force Modulation AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm