Tipless AFM Cantilevers

Special AFM probes with tipless AFM cantilevers
29 results matching your criteria
best of the best
TL-CONT

TL-CONT

Tipless Contact Mode AFM Cantilever
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
TL-FM

TL-FM

Tipless Force Modulation AFM Cantilever
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
TL-NCH

TL-NCH

Tipless Tapping Mode AFM Cantilever
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
330kHz
C
42 N/m
L
125 µm
TL-NCL

TL-NCL

Tipless, Long Tapping Mode AFM Cantilever
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
190kHz
C
48 N/m
L
225 µm
the industry standard
ARROW-TL1

ARROW-TL1

Tipless AFM Cantilever for Special Applications
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
6kHz
C
0.03 N/m
L
500 µm
PNP-TR-TL

PNP-TR-TL

Tipless Silicon Nitride AFM Cantilever
Coating: Reflex Gold
Tip Shape: Tipless
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
ARROW-TL2

ARROW-TL2

Tipless AFM Cantilever Array for Special Applications
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 2
1
F
6kHz
C
0.03 N/m
L
500 µm
ARROW-TL8

ARROW-TL8

Tipless AFM Cantilever Array for Special Applications
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 8
1
F
6kHz
C
0.03 N/m
L
500 µm
HQ:NSC35/tipless/No Al

HQ:NSC35/tipless/No Al

Tipless AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205kHz
300kHz
150kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/tipless/No Al

HQ:NSC36/tipless/No Al

Tipless AFM Probe with 3 Different Force Modulation AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90kHz
130kHz
65kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:CSC37/tipless/No Al

HQ:CSC37/tipless/No Al

Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
40kHz
20kHz
30kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
top value
HQ:CSC38/tipless/No Al

HQ:CSC38/tipless/No Al

Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
20kHz
10kHz
14kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
best bang for your buck
All-In-One-Tipless

All-In-One-Tipless

Tipless AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 4
1
2
3
4
F
15kHz
80kHz
150kHz
350kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
ARROW-TL1Au

ARROW-TL1Au

Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating: Gold on Sample Facing Side
Tip Shape: Tipless
AFM Cantilever:
F
6kHz
C
0.03 N/m
L
500 µm
ARROW-TL2Au

ARROW-TL2Au

Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating: Gold on Sample Facing Side
Tip Shape: Tipless
AFM Cantilevers: 2
1
F
6kHz
C
0.03 N/m
L
500 µm
ARROW-TL8Au

ARROW-TL8Au

Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating: Gold on Sample Facing Side
Tip Shape: Tipless
AFM Cantilevers: 8
1
F
6kHz
C
0.03 N/m
L
500 µm
PNP-TR-TL-Au

PNP-TR-TL-Au

Tipless, Gold Coated Silicon Nitride AFM Cantilever
Coating: Gold Overall
Tip Shape: Tipless
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
HQ:NSC35/tipless/Cr-Au

HQ:NSC35/tipless/Cr-Au

Tipless AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205kHz
300kHz
150kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/tipless/Cr-Au

HQ:NSC36/tipless/Cr-Au

Tipless AFM Probe with 3 Different Gold Coated Force Modulation AFM Cantilevers
Coating: Gold Overall
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90kHz
130kHz
65kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
Mix and Match Box

Mix and Match Box

Mixed box: up to 400 MikroMasch AFM probes
Coating: various
Tip Shape: various
2