NanoAndMore GmbH does not ship to your country
Rectangular Cross Section AFM Cantilevers
AFM probes with rectangular cross section AFM cantilevers
Sort by:
49 results
![55AC-NN](/uploads/media/default/0001/02/thumb_1991_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
55AC-NN
Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
![PNP-TRS](/uploads/media/default/0001/02/thumb_1447_default_small_100_100.png)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
PNP-TRS
Silicon Nitride AFM Probe Single Cantilever Compatible with ScanAsyst®** Mode
Coating:
Reflective Gold
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilever:
F
67 kHz
C
0.32 N/m
L
100 µm
top value
![240AC-NG](/uploads/media/default/0001/02/thumb_1580_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
240AC-NG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
![240AC-MA](/uploads/media/default/0001/02/thumb_1591_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
240AC-MA
Hard Magnetic, Medium Momentum AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Magnetic
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
![3XC-NA](/uploads/media/default/0001/02/thumb_1995_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
3XC-NA
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
![160AC-NN](/uploads/media/default/0001/02/thumb_1581_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
160AC-NN
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
![240AC-NN](/uploads/media/default/0001/02/thumb_1581_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
240AC-NN
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
![3XC-NN](/uploads/media/default/0001/02/thumb_1995_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
3XC-NN
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
![4XC-NN](/uploads/media/default/0001/02/thumb_1568_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
4XC-NN
AFM Probe with 4 Different AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm
best bang for your buck
![SiNi](/uploads/media/default/0001/02/thumb_1666_default_small_100_100.png)
![BudgetSensors BudgetSensors](/img/logos/budgetsensors.com_small.jpg)
SiNi
Silicon Nitride AFM Probe with 2 Different AFM Cantilevers on Each Side of the Chip
Coating:
Reflective Gold
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilevers: 4
1
2
F
30 kHz
10 kHz
C
0.27 N/m
0.06 N/m
L
100 µm
200 µm
top value
![160AC-FG](/uploads/media/default/0001/02/thumb_1957_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
160AC-FG
High Aspect Ratio, Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
![240AC-FG](/uploads/media/default/0001/02/thumb_1955_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
240AC-FG
High Aspect Ratio, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
![PNP-TR-Au](/uploads/media/default/0001/01/thumb_366_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
PNP-TR-Au
Gold Coated Silicon Nitride AFM Probe
Coating:
Gold Overall
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
![3XC-GG](/uploads/media/default/0001/02/thumb_1995_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
3XC-GG
AFM Probe with 3 Different Gold Coated AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
![4XC-GG](/uploads/media/default/0001/02/thumb_1568_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
4XC-GG
AFM Probe with 4 Different Gold Coated AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm
![240AC-GG](/uploads/media/default/0001/02/thumb_1589_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
240AC-GG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
![XNC12/Cr-Au](/uploads/media/default/0001/07/thumb_6354_default_small_100_100.jpeg)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
XNC12/Cr-Au
AFM Probe with 2 Different Gold Coated Silicon Nitride AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
17 kHz
67 kHz
C
0.08 N/m
0.32 N/m
L
200 µm
100 µm
![Mix and Match Box](/uploads/media/default/0001/02/thumb_1434_default_small_100_100.png)
![MikroMasch MikroMasch](/img/logos/spmtips.com_small.jpg)
Mix and Match Box
Mixed box: up to 400 MikroMasch AFM probes
Coating:
various
Tip Shape: various
Tip Shape: various
![160AC-GG](/uploads/media/default/0001/02/thumb_1589_default_small_100_100.jpeg)
![OPUS by MikroMasch OPUS by MikroMasch](/img/logos/opustips.com_small.jpg)
160AC-GG
Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
![PNP-TR-TL](/uploads/media/default/0001/01/thumb_365_default_small_100_100.jpeg)
![NanoWorld NanoWorld](/img/logos/nanoworld.com_small.jpg)
PNP-TR-TL
Tipless Silicon Nitride AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm