AFM Probes » CP-NCH-PM

 Order
 Request a quote (RFQ)
Order Code / Price*
Quantity
CP-NCH-PM-D-5 Box of 5 AFM Probes
500.00 USD
sphere Ø = 9.57 µm
Volume Discount Available [?]
CP-NCH-PM-E-5 Box of 5 AFM Probes
500.00 USD
sphere Ø = 14.59 µm
CP-NCH-PM-A-5 Box of 5 AFM Probes
500.00 USD
sphere Ø = 1.5 µm
CP-NCH-PM-B-5 Box of 5 AFM Probes
500.00 USD
sphere Ø = 3.36 µm
CP-NCH-PM-C-5 Box of 5 AFM Probes
500.00 USD
sphere Ø = 6.44 µm
Product availability: On demand - 14 days delivery time

CP-NCH-PM

Colloidal probe, AFM cantilever with round tip like a ball.

Coating: none
Tip shape: Sphere
Cantilever:
F 330 kHz
C 42 N/m
L 125 µm
*nominal values

Applications

The new sQube® colloidal probe combines the well-known features of the proven NANOSENSORS™ NCH series such as high application versatility and compatibility with most commercial SPMs with a reproducible sphere radius instead of a sharp tip. The excellent  radius and the minimized variation of diameter provide reproducible signals.

PPP-NCH AFM probes are designed for non-contact mode or tapping mode AFM (also known as: attractive or dynamic mode). 

The so called "Colloidal Probe Technique", where single colloids are attached to AFM cantilevers for force measurements, opens the chance for a better understanding of fundamental interactions in a variety of fields.

Examples are adhesion phenomena, particle-surface-interactions, mechanical properties, suspensions, hydrodynamics and boundary slip - to name just some out of an increasing number of applications.

The probe offers unique features:

        - sphere material: polymethylmethacrylate (PMMA)
        - excellent sphere diameter:
          A = 1.5 µm, B = 3.36 µm, C = 6.44 µm, D = 9.57 µm, or E = 14.59 µm (all +/- 5%)
          (Due to different masses the resonance frequency can differ.)
          Please choose A, B, C, D, or E  when ordering!
        - highly doped silicon cantilever to dissipate static charge
        - chemically inert
        - high mechanical Q-factor for high sensitivity
        - precise alignment of the cantilever position when used together with the Alignment chip
          (within +/- 2 µm)
        - compatible with PointProbe® Plus XY-Alignment Series

This product features alignment grooves on the back side of the holder chip.

None

AFM Cantilever:

  • Beam
  • 42 N/m (10 - 130 N/m)*
  • 330 kHz (204 - 497 kHz)*
  • 125 µm (115 - 130 µm)*
  • 30 µm (22.5 - 37.5 µm)*
  • 4 µm (3 - 5 µm)*
  • * typical range