Uncoated AFM Tips

AFM probes with uncoated AFM tips
263 results matching your criteria
best of the best
PPP-NCHR

PPP-NCHR

Standard Tapping Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F
330kHz
C
42 N/m
L
125 µm
ATEC-NC

ATEC-NC

Tapping Mode AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
AFM Cantilever:
F
335kHz
C
45 N/m
L
160 µm
the industry standard
NCHR

NCHR

Standard Tapping Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F
320kHz
C
42 N/m
L
125 µm
TESPA

TESPA

Standard Tapping Mode AFM Probe

Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F
320kHz
C
42 N/m
L
125 µm
ARROW-NCR

ARROW-NCR

Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: Arrow
AFM Cantilever:
F
285kHz
C
42 N/m
L
160 µm
top value
HQ:NSC15/Al BS

HQ:NSC15/Al BS

Standard Tapping Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
325kHz
C
40 N/m
L
125 µm
top value
160AC-NA

160AC-NA

Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: OPUS
AFM Cantilever:
F
300kHz
C
26 N/m
L
160 µm
best bang for your buck
Tap300Al-G

Tap300Al-G

Standard Tapping Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
300kHz
C
40 N/m
L
125 µm
OTESPA

OTESPA

Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: OPUS
AFM Cantilever:
F
300kHz
C
26 N/m
L
160 µm
PPP-NCLR

PPP-NCLR

Tapping Mode AFM Probe, Long AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F
190kHz
C
48 N/m
L
225 µm
NCLR

NCLR

Tapping Mode AFM Probe, Long Cantilever
Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F
190kHz
C
48 N/m
L
225 µm
HQ:NSC16/Al BS

HQ:NSC16/Al BS

Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
190kHz
C
45 N/m
L
225 µm
Tap190Al-G

Tap190Al-G

Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
190kHz
C
48 N/m
L
225 µm
EBD-NCH

EBD-NCH

Universal EBD whisker for enhanced resolution, imaging stability and tip lifetime
Coating: none
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
best of the best
PPP-QNCHR

PPP-QNCHR

Tapping Mode AFM Probe, for UHV Conditions
Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F
330kHz
C
42 N/m
L
125 µm
PPP-RT-NCHR

PPP-RT-NCHR

Standard Tapping Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
330kHz
C
42 N/m
L
125 µm
best of the best
PPP-NCSTR

PPP-NCSTR

Soft Tapping Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160kHz
C
7.4 N/m
L
150 µm
the industry standard
NCSTR

NCSTR

Soft Tapping Mode AFM Probe

Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160kHz
C
7.4 N/m
L
150 µm
top value
HQ:NSC14/Al BS

HQ:NSC14/Al BS

Soft Tapping Mode AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
160kHz
C
5 N/m
L
125 µm
HQ:NSC35/Al BS

HQ:NSC35/Al BS

AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205kHz
300kHz
150kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
14