AFM Probes for Life Science

108 results matching your criteria
PPP-NCHAuD

PPP-NCHAuD

Gold Coated Tapping Mode AFM Probe
Coating: Reflex Gold
Tip Shape: Standard
Cantilever:
F 330 kHz
C 42 N/m
L 125 µm
best of the best
qp-BioAC

qp-BioAC

uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 3 different cantilevers

Coating: Reflex Gold
Tip Shape: Circular symmetric
Cantilevers: 3
F 90 kHz
C 0.3 N/m
L 40 µm
F 50 kHz
C 0.1 N/m
L 60 µm
F 30 kHz
C 0.06 N/m
L 80 µm
PPP-NCSTAuD

PPP-NCSTAuD

Gold Coated Soft Tapping Mode AFM Probe
Coating: Reflex Gold
Tip Shape: Standard
Cantilever:
F 160 kHz
C 7.4 N/m
L 150 µm
PPP-FMAuD

PPP-FMAuD

Gold Coated Force Modulation AFM Probe
Coating: Reflex Gold
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
ARROW-UHFAuD

ARROW-UHFAuD

Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever

Coating: Reflex Gold
Tip Shape: Arrow
Cantilever:
F 2000 kHz
L 35 µm
USC-F1.2-k0.15

USC-F1.2-k0.15

Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflex Gold
Tip Shape: Cone Shaped,EBD
Cantilever:
F 1200 kHz
C 0.15 N/m
L 7 µm
best of the best
qp-fast

qp-fast

uniqprobe™ for Soft/Standard/Fast Tapping/Dynamic AFM imaging
Coating: Reflex Gold
Tip Shape: Circular symmetric
Cantilevers: 3
F 800 kHz
C 80 N/m
L 40 µm
F 420 kHz
C 30 N/m
L 60 µm
F 250 kHz
C 15 N/m
L 80 µm
Special Developments

Special Developments

Download a List of Non-Standard, Special AFM Probes and More

Coating: various
Tip Shape: various
top value
HQ:NSC18/Cr-Au BS

HQ:NSC18/Cr-Au BS

Gold Coated Force Modulation AFM Probe
Coating: Reflex Gold
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
160AC-NG

160AC-NG

Gold Coated Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Gold
Tip Shape: OPUS
Cantilever:
F 300 kHz
C 26 N/m
L 160 µm
Tap150GD-G

Tap150GD-G

Gold Coated Soft Tapping Mode Probe
Coating: Reflex Chromium/Gold
Tip Shape: Rotated
Cantilever:
F 150 kHz
C 5 N/m
L 125 µm
The Standard Silicon Nitride AFM probe
PNP-TR

PNP-TR

Silicon Nitride AFM Probe
Coating: Reflex Gold
Tip Shape: Pyramid
Cantilevers: 4
F 67 kHz
C 0.32 N/m
L 100 µm
F 17 kHz
C 0.08 N/m
L 200 µm
biotool cell

biotool cell

EBD carbon whisker with 25 nm radius on soft cantilever
Coating: Reflex Gold
Tip Shape: Cone Shaped,EBD
Cantilever:
F 50 kHz
C 0.1 N/m
L 60 µm
qp-BioT

qp-BioT

uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 2 different triangular cantilevers

Coating: Reflex Gold
Tip Shape: Circular symmetric
Cantilevers: 2
F 50 kHz
C 0.3 N/m
L 100 µm
F 20 kHz
C 0.08 N/m
L 200 µm
PPP-NCLAuD

PPP-NCLAuD

Gold Coated Tapping Mode AFM Probe with Long Cantilever
Coating: Reflex Gold
Tip Shape: Standard
Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
best of the best
qp-HBC

qp-HBC

uniqprobe™ - HeartBeat Cantilever for ScanAsyst** and Peak Force Tapping**
Coating: Reflex Aluminum
Tip Shape: Circular symmetric
Cantilevers: 2
F 60 kHz
C 0.5 N/m
L 115 µm
USC-F0.3-k0.3

USC-F0.3-k0.3

Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflex Gold
Tip Shape: Cone Shaped,EBD
Cantilever:
F 300 kHz
C 0.3 N/m
L 20 µm
PNP-DB

PNP-DB

Silicon Nitride AFM Probe
Coating: Reflex Gold
Tip Shape: Pyramid
Cantilevers: 4
F 67 kHz
C 0.48 N/m
L 100 µm
F 17 kHz
C 0.06 N/m
L 200 µm
biotool high resolution

biotool high resolution

EBD carbon whisker with 2 nm radius on soft cantilever
Coating: Reflex Gold
Tip Shape: EBD,Cone Shaped,Supersharp
Cantilever:
F 50 kHz
C 0.1 N/m
L 60 µm
top value
XNC12/Cr-Au BS

XNC12/Cr-Au BS

AFM Probe with 2 Different Gold Coated Silicon Nitride Cantilevers on Each Side of the Chip
Coating: Reflex Gold
Tip Shape: Pyramid
Cantilevers: 4
F 17 kHz
C 0.08 N/m
L 200 µm
F 67 kHz
C 0.32 N/m
L 100 µm
6