Force Modulation (FM) AFM Probes

127 results matching your criteria
ATEC-FM

ATEC-FM

Force Modulation AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
Cantilever:
F 85 kHz
C 2.8 N/m
L 240 µm
best of the best
PPP-FMR

PPP-FMR

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2 N/m
L 225 µm
ARROW-FMR

ARROW-FMR

Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: Arrow
Cantilever:
F 75 kHz
C 2.8 N/m
L 240 µm
the industry standard
FMR

FMR

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
HQ:NSC18/Al BS

HQ:NSC18/Al BS

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
240AC-NA

240AC-NA

Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: OPUS
Cantilever:
F 70 kHz
C 2 N/m
L 240 µm
best bang for your buck
Multi75Al-G

Multi75Al-G

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 3 N/m
L 225 µm
OLTESPA

OLTESPA

Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: OPUS
Cantilever:
F 70 kHz
C 2 N/m
L 240 µm
PPP-RT-FMR

PPP-RT-FMR

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
PPP-QFMR

PPP-QFMR

Force Modulation AFM Probe, for UHV Conditions
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
PPP-FMAuD

PPP-FMAuD

Gold Coated Force Modulation AFM Probe
Coating: Reflex (Au)
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
Special Developments

Special Developments

Download a List of Non-Standard, Special AFM Probes and More
Coating: various
Tip Shape: various
HQ:NSC18/Cr-Au BS

HQ:NSC18/Cr-Au BS

Gold Coated Force Modulation AFM Probe
Coating: Reflex (Au)
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
HQ:XSC11/Al BS

HQ:XSC11/Al BS

AFM Probe with 4 Different Cantilevers for Various Applications
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilevers: 4
F 15 kHz
C 0.2 N/m
L 500 µm
F 80 kHz
C 2.7 N/m
L 210 µm
F 155 kHz
C 7 N/m
L 150 µm
F 350 kHz
C 42 N/m
L 100 µm
HQ:NSC36/Cr-Au BS

HQ:NSC36/Cr-Au BS

AFM Probe with 3 Different Gold Coated Force Modulation Mode Cantilevers
Coating: Reflex (Au)
Tip Shape: Rotated
Cantilevers: 3
F 90 kHz
C 1 N/m
L 110 µm
F 130 kHz
C 2 N/m
L 90 µm
F 65 kHz
C 0.6 N/m
L 130 µm
HQ:NSC19/Al BS

HQ:NSC19/Al BS

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilever:
F 65 kHz
C 0.5 N/m
L 125 µm
Mix and Match Box

Mix and Match Box

Mixed box: up to 400 MikroMasch AFM probes
Coating: various
Tip Shape: various
All-In-One-Al

All-In-One-Al

AFM Probe with 4 Different Cantilevers for Various Applications
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilevers: 4
F 15 kHz
C 0.2 N/m
L 500 µm
F 80 kHz
C 2.7 N/m
L 210 µm
F 150 kHz
C 7.4 N/m
L 150 µm
F 350 kHz
C 40 N/m
L 100 µm
240AC-NG

240AC-NG

Gold Coated Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex (Au)
Tip Shape: OPUS
Cantilever:
F 70 kHz
C 2 N/m
L 240 µm
Multi75GD-G

Multi75GD-G

Gold Coated Force Modulation AFM Probe
Coating: Reflex (Au)
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 3 N/m
L 225 µm
7