Spherical AFM Tips

AFM probes with spherical active part of the AFM tips
67 results matching your criteria
New
biosphere B20-NCH

biosphere B20-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B20-FM

biosphere B20-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B20-CONT

biosphere B20-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B30-NCH

biosphere B30-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B30-FM

biosphere B30-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B30-CONT

biosphere B30-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B40-NCH

biosphere B40-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B40-FM

biosphere B40-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
Special Developments

Special Developments

Download a List of Non-Standard, Special AFM Probes and More

Coating: various
Tip Shape: various
New
biosphere B40-CONT

biosphere B40-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B50-NCH

biosphere B50-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B50-FM

biosphere B50-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B50-CONT

biosphere B50-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B100-NCH

biosphere B100-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B100-FM

biosphere B100-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B100-CONT

biosphere B100-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B150-NCH

biosphere B150-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B150-FM

biosphere B150-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B150-CONT

biosphere B150-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B300-NCH

biosphere B300-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
4