PPP-XYNCSTR

Soft Tapping Mode AFM Probe with Special Alignment System

Coating: Reflex Aluminum
Tip shape: Standard
Cantilever:
F 160 kHz
C 7.4 N/m
L 150 µm
*nominal values

The XY-auto-alignment probes for Non-Contact / Soft Tapping mode application with a Reflex coating extend the plug-and-fit alignment concept of the Alignment Chip (ALIGN) to 150 µm short cantilevers optimized for non-contact / soft tapping mode applications. Probe exchange with a tip repositioning accuracy of better than ± 8µm is possible for all probes of the XY-alignment probes series – independent of their cantilever length. This series is adjusted to the tip position of probes with a cantilever length of 225µm.

As a matter of course, the features of the proven PointProbe® Plus series such as high application versatility, compatibility with most commercial SPMs, extremely low and reproducible tip radius as well as a precisely defined tip shape are maintained. The excellent tip radius and the minimized variation in tip shape provide more reproducible images and enhanced resolution.

NANOSENSORS™ PPP-XYNCSTR AFM probes are designed for non-contact or soft tapping mode imaging. The combination of soft cantilever and fairly high resonance frequency enables stable and fast measurements with reduced tip-sample interaction. This feature significantly reduces tip wear and sample wear at the same time.

The probe offers unique features:

  • excellent tip radius of curvature
  • highly doped silicon to dissipate static charge
  • Al coating on detector side of cantilever
  • chemically inert
  • high mechanical Q-factor for high sensitivity
  • tip repositioning accuracy better than ± 8 µm (in combination with Alignment Chip)
The reflex coating is an approximately 30 nm thick aluminum coating on the detector side of the cantilever which enhances the reflectivity of the laser beam by a factor of about 2.5. Furthermore it prevents light from interfering within the cantilever. The virtually stress-free coating is bending the cantilever less than 3.5% of the cantilever length.

AFM Tip:

  • AFM Cantilever:

  • Beam
  • 150 µm (140 - 160 µm)*
  • 27 µm (19.5 - 34.5 µm)*
  • 2.8 µm (1.8 - 3.8 µm)*
  • 7.4 N/m (1.2 - 29 N/m)*
  • 160 kHz (75 - 265 kHz)*
  • * guaranteed range This product features alignment grooves on the back side of the holder chip.