Nanoindentation and Lithography AFM Probes

AFM probes with hardened AFM tips for nanomechanical testing and sample mechanical modification
62 results matching your criteria
HQ:CSC17/Hard/Al BS

HQ:CSC17/Hard/Al BS

Long Scanning, DLC Hardened Contact Mode AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
13kHz
C
0.18 N/m
L
450 µm
ContDLC

ContDLC

Diamond-Like-Carbon Coated Contact Mode AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
BudgetComboBox

BudgetComboBox

Mixed Box with 50 BudgetSensors AFM probes of your choice
Coating: various
Tip Shape: various
All-In-One-DLC

All-In-One-DLC

Diamond-Like-Carbon Coated AFM Probe with 4 Different Cantilevers for Various Applications
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15kHz
80kHz
150kHz
350kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
200 µm
150 µm
100 µm
top value
HQ:DMD-XSC11

HQ:DMD-XSC11

AFM Probe with 4 Different Diamond Coated, Conductive Cantilevers for Various Applications
Coating: Conductive Diamond
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
18kHz
110kHz
210kHz
450kHz
C
0.5 N/m
6.5 N/m
18 N/m
95 N/m
L
500 µm
210 µm
150 µm
100 µm
New
biosphere B20-NCH

biosphere B20-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B20-FM

biosphere B20-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B20-CONT

biosphere B20-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B30-NCH

biosphere B30-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B30-FM

biosphere B30-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B30-CONT

biosphere B30-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B40-NCH

biosphere B40-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B40-FM

biosphere B40-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B40-CONT

biosphere B40-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B50-NCH

biosphere B50-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B50-FM

biosphere B50-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B50-CONT

biosphere B50-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
New
biosphere B100-NCH

biosphere B100-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
330kHz
C
40 N/m
L
125 µm
New
biosphere B100-FM

biosphere B100-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
75kHz
C
2.8 N/m
L
225 µm
New
biosphere B100-CONT

biosphere B100-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilever:
F
13kHz
C
0.2 N/m
L
450 µm
4