High Density Carbon AFM Tips (Electron Beam Deposited)

AFM probes with high density carbon (HDC) electron beam deposited (EBD) AFM tips
Sort by:
55 results
EBD-NCH
EBD-NCH
Universal EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating: none
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
USC-F1.2-k0.15
USC-F1.2-k0.15
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1200 kHz
C
0.15 N/m
L
7 µm
New
biotool cell
biotool cell
EBD carbon whisker with 25 nm radius on soft AFM cantilever
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm
USC-F0.3-k0.3
USC-F0.3-k0.3
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
300 kHz
C
0.3 N/m
L
20 µm
USC-F5-k30
USC-F5-k30
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
5000 kHz
C
30 N/m
L
10 µm
New
biotool high resolution
biotool high resolution
EBD carbon AFM whisker with 2 nm radius on soft AFM cantilever
Coating: Reflective Gold
Tip Shape: EBD,Cone Shaped,Supersharp
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm
New
biotool cell XXL
biotool cell XXL
Extralong 15 um EBD carbon whisker with 25 nm radius on soft AFM cantilever
Coating: Reflective Gold
Tip Shape: EBD,Cone Shaped
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm
SuperSharp Enhanced
SuperSharp Enhanced
Ultrasharp EBD AFM whisker for high-resolution, non-contact AFM
Coating: Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
SuperSharpStandard-NCH
SuperSharpStandard-NCH
SuperSharp diamond-like EBD whisker for non-contact AFM
Coating: Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
SuperSharp Enhanced-soft
SuperSharp Enhanced-soft
Ultrasharp EBD AFM whisker for high-resolution, soft tapping AFM
Coating: Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
USC-F2-k3
USC-F2-k3
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
2000 kHz
C
3 N/m
L
10 µm
USC-F1.2-k7.3
USC-F1.2-k7.3
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1200 kHz
C
7.3 N/m
L
20 µm
EBD-AR15T
EBD-AR15T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
USC-F1.5-k0.6
USC-F1.5-k0.6
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1500 kHz
C
0.6 N/m
L
7 µm
M-CIS
M-CIS
EBD AFM whisker for non-contact AFM microlens contact image sensor (CIS) inspection
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
EBD-HAR
EBD-HAR
Universal high-aspect ratio EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
EBD-AR20T
EBD-AR20T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
M1-HAR
M1-HAR
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
SuperSharpStandard-FM
SuperSharpStandard-FM
SuperSharp diamond-like EBD AFM whisker for soft tapping AFM
Coating: Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
New
biosphere B20-NCH
biosphere B20-NCH
Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflective Gold
Tip Shape: Sphere, Diamond-Like-Carbon
Sphere Diameter: 0.04 µm
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
3