Borosilicate Glass AFM Support Chips

AFM probes with borosilicate glass support chips
14 results matching your criteria
The Standard Silicon Nitride AFM probe
PNP-TR

PNP-TR

Silicon Nitride AFM Probe
Coating: Reflex Gold
Tip Shape: Pyramid
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
PNP-DB

PNP-DB

Silicon Nitride AFM Probe
Coating: Reflex Gold
Tip Shape: Pyramid
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.48 N/m
0.06 N/m
L
100 µm
200 µm
top value
XNC12/Cr-Au BS

XNC12/Cr-Au BS

AFM Probe with 2 Different Gold Coated Silicon Nitride AFM Cantilevers on Each Side of the Chip
Coating: Reflex Gold
Tip Shape: Pyramid
AFM Cantilevers: 4
1
2
F
17kHz
67kHz
C
0.08 N/m
0.32 N/m
L
200 µm
100 µm
PNP-TRS

PNP-TRS

Silicon Nitride AFM Probe Single Cantilever Compatible with ScanAsyst®** Mode

Coating: Reflex Gold
Tip Shape: Pyramid
AFM Cantilever:
F
67kHz
C
0.32 N/m
L
100 µm
PNP-TR-Au

PNP-TR-Au

Gold Coated Silicon Nitride AFM Probe

Coating: Gold Overall
Tip Shape: Pyramid
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
XNC12/Cr-Au

XNC12/Cr-Au

AFM Probe with 2 Different Gold Coated Silicon Nitride AFM Cantilevers on Each Side of the Chip
Coating: Gold Overall
Tip Shape: Pyramid
AFM Cantilevers: 4
1
2
F
17kHz
67kHz
C
0.08 N/m
0.32 N/m
L
200 µm
100 µm
Mix and Match Box

Mix and Match Box

Mixed box: up to 400 MikroMasch AFM probes
Coating: various
Tip Shape: various
PNP-TR-TL

PNP-TR-TL

Tipless Silicon Nitride AFM Cantilever
Coating: Reflex Gold
Tip Shape: Tipless
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
PNP-TR-TL-Au

PNP-TR-TL-Au

Tipless, Gold Coated Silicon Nitride AFM Cantilever
Coating: Gold Overall
Tip Shape: Tipless
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
CP-PNP-Au

CP-PNP-Au

Colloidal probe, AFM cantilever with round tip like a ball.
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
CP-PNP-SiO

CP-PNP-SiO

Colloidal probe, AFM cantilever with round tip like a ball.
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
CP-PNP-BSG

CP-PNP-BSG

Colloidal probe, AFM cantilever with round tip like a ball.

Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
CP-PNP-PM

CP-PNP-PM

Colloidal probe, AFM cantilever with round tip like a ball.
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
CP-PNP-PS

CP-PNP-PS

Colloidal probe, AFM cantilever with round tip like a ball.
Coating: Reflex Gold
Tip Shape: Sphere
AFM Cantilevers: multiple
F
67kHz
17kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
1