Backside Gold Coated AFM Cantilevers

Sort by:
66 results
PPP-NCHAuD
PPP-NCHAuD
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
top value
HiRes-C15/Cr-Au
HiRes-C15/Cr-Au
High Resolution, Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Supersharp
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
HiRes-C19/Cr-Au
HiRes-C19/Cr-Au
High Resolution, Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Supersharp
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
best bang for your buck
SHR150
SHR150
High Resolution Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Supersharp
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
best of the best
qp-BioAC
qp-BioAC
uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 3 different AFM cantilevers
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 3
1
2
3
F
90 kHz
50 kHz
30 kHz
C
0.3 N/m
0.1 N/m
0.06 N/m
L
40 µm
60 µm
80 µm
PPP-NCSTAuD
PPP-NCSTAuD
Gold Coated Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-FMAuD
PPP-FMAuD
Gold Coated Force Modulation AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ARROW-UHFAuD
ARROW-UHFAuD

Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever

Coating: Reflective Gold
Tip Shape: Arrow
AFM Cantilever:
F
2000 kHz
C
x
L
35 µm
USC-F1.2-k0.15
USC-F1.2-k0.15
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1200 kHz
C
0.15 N/m
L
7 µm
HQ:NSC14/Cr-Au BS
HQ:NSC14/Cr-Au BS
Gold Coated Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
best of the best
qp-fast
qp-fast
uniqprobe™ for Soft/Standard/Fast Tapping/Dynamic AFM imaging
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 3
1
2
3
F
800 kHz
420 kHz
250 kHz
C
80 N/m
30 N/m
15 N/m
L
40 µm
60 µm
80 µm
top value
HQ:NSC18/Cr-Au BS
HQ:NSC18/Cr-Au BS
Gold Coated Force Modulation AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
Tap150GD-G
Tap150GD-G
Gold Coated Soft Tapping Mode Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
The Standard SiNi probe
PNP-TR
PNP-TR
Silicon Nitride AFM Probe
Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
New
biotool cell
biotool cell
EBD carbon whisker with 25 nm radius on soft AFM cantilever
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm
qp-BioT
qp-BioT
uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 2 different triangular AFM cantilevers
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 2
1
2
F
50 kHz
20 kHz
C
0.3 N/m
0.08 N/m
L
100 µm
200 µm
best bang for your buck
Multi75GD-G
Multi75GD-G
Gold Coated Force Modulation AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
PPP-NCLAuD
PPP-NCLAuD
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
New
qp-BioAC-CI
qp-BioAC-CI
uniqprobe™ BioAC with Rounded AFM Tips for Cell Imaging
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 3
1
2
3
F
90 kHz
50 kHz
30 kHz
C
0.3 N/m
0.1 N/m
0.06 N/m
L
40 µm
60 µm
80 µm
USC-F0.3-k0.3
USC-F0.3-k0.3
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
300 kHz
C
0.3 N/m
L
20 µm
4