Back Side Aluminum Coated AFM Cantilevers

AFM probes with back side aluminum coated AFM cantilevers
Sort by:
133 results
best of the best
PPP-NCHR
PPP-NCHR
Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
New
PPP-NCR
PPP-NCR
Standard Tapping Mode AFM Probe with AC160 mechanical properties
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
300 kHz
C
26 N/m
L
125 µm
the industry standard
NCHR
NCHR
Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
TESPA
TESPA

Standard Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
ARROW-NCR
ARROW-NCR
Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflective Aluminum
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
top value
HQ:NSC15/Al BS
HQ:NSC15/Al BS
Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
top value
160AC-NA
160AC-NA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
OMCL-AC160TS
OMCL-AC160TS
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
best bang for your buck
Tap300Al-G
Tap300Al-G
Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
OTESPA
OTESPA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
PPP-NCLR
PPP-NCLR
Tapping Mode AFM Probe, Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCLR
NCLR
Tapping Mode AFM Probe, Long Cantilever
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
HQ:NSC16/Al BS
HQ:NSC16/Al BS
Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
Tap190Al-G
Tap190Al-G
Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
best of the best
PPP-QNCHR
PPP-QNCHR
Tapping Mode AFM Probe, for UHV Conditions
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-RT-NCHR
PPP-RT-NCHR
Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
best of the best
PPP-NCSTR
PPP-NCSTR
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
the industry standard
NCSTR
NCSTR

Soft Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
top value
HQ:NSC14/Al BS
HQ:NSC14/Al BS
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
HQ:NSC35/Al BS
HQ:NSC35/Al BS
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
7