Rotated AFM Tips

AFM probes with rotated 4-sided pyramidal macroscopic shape of the AFM tips
Sort by:
120 results
Tap300GD-G
Tap300GD-G
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
Tap190GD-G
Tap190GD-G
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
top value
HQ:NSC18/Co-Cr/Al BS
HQ:NSC18/Co-Cr/Al BS
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC36/Co-Cr/Al BS
HQ:NSC36/Co-Cr/Al BS
Hard Magnetic, Medium Momentum MFM AFM Probe with 3 Different AFM Cantilevers
Coating: Magnetic
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
60 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
best bang for your buck
MagneticMulti75-G
MagneticMulti75-G
Hard Magnetic, Medium Momentum AFM Probe
Coating: Magnetic
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
HQ:NSC15/No Al
HQ:NSC15/No Al
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
HQ:NSC16/No Al
HQ:NSC16/No Al
Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
Tap300-G
Tap300-G
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
Tap190-G
Tap190-G
Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
HQ:NSC36/Al BS
HQ:NSC36/Al BS
AFM Probe with 3 Different Force Modulation Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
Tap150-G
Tap150-G
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
HQ:NSC14/No Al
HQ:NSC14/No Al
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
HQ:NSC18/No Al
HQ:NSC18/No Al
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC19/No Al
HQ:NSC19/No Al
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
HQ:NSC35/No Al
HQ:NSC35/No Al
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: none
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/No Al
HQ:NSC36/No Al
AFM Probe with 3 Different Force Modulation Mode AFM Cantilevers
Coating: none
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
Multi75-G
Multi75-G
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
HQ:XSC11/No Al
HQ:XSC11/No Al
AFM Probe with 4 Different Cantilevers for Various Applications
Coating: none
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm
All-In-One
All-In-One
AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating: none
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
HiRes-C18/Cr-Au
HiRes-C18/Cr-Au
High Resolution, Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
6