AFM Tips at the Very End of the AFM Cantilever

AFM probes with 3-sided pyramidal macroscopic shape of the AFM tips for optimized positioning upon sample (OPUS)
26 results matching your criteria
top value
160AC-NA

160AC-NA

Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
OTESPA

OTESPA

Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
200AC-NA

200AC-NA

Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
135 kHz
C
9 N/m
L
200 µm
top value
240AC-NA

240AC-NA

Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
OLTESPA

OLTESPA

Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
160AC-SG

160AC-SG

High Resolution, Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold,Reflective Gold
Tip Shape: Supersharp,Optimized Positioning,Supersharp,Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
240AC-SG

240AC-SG

High Resolution, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Supersharp,Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
240AC-PP

240AC-PP

Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
OSCM-PT

OSCM-PT

Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
160AC-NG

160AC-NG

Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
55AC-NG

55AC-NG

Gold Coated Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value
55AC-NA

55AC-NA

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
55AC-NN

55AC-NN

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value
240AC-NG

240AC-NG

Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
240AC-MA

240AC-MA

Hard Magnetic, Medium Momentum AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Magnetic
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
3XC-NA

3XC-NA

AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM  Tips at the Very End of the AFM Cantilevers

Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
160AC-NN

160AC-NN

Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
240AC-NN

240AC-NN

Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
3XC-NN

3XC-NN

AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM  Tips at the Very End of the AFM Cantilevers
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
4XC-NN

4XC-NN

AFM Probe with 4 Different AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm
2