Life Science AFM Probes

Biological applications
108 results matching your criteria
PPP-NCHAu

PPP-NCHAu

Gold Coated Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F 330 kHz
C 42 N/m
L 125 µm
PPP-NCLAu

PPP-NCLAu

Gold Coated Tapping Mode AFM Probe with Long Cantilever
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
ATEC-NCAu

ATEC-NCAu

Gold Coated Tapping Mode AFM Probe with REAL Tip Visibility
Coating: Gold Overall
Tip Shape: Visible
AFM Cantilever:
F 335 kHz
C 45 N/m
L 160 µm
Tap300GB-G

Tap300GB-G

Gold Coated Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F 300 kHz
C 40 N/m
L 125 µm
Tap190GB-G

Tap190GB-G

Gold Coated Tapping Mode AFM Probe with Long Cantilever
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
160AC-GG

160AC-GG

Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Gold Overall
Tip Shape: OPUS
AFM Cantilever:
F 300 kHz
C 26 N/m
L 160 µm
HQ:NSC14/Cr-Au

HQ:NSC14/Cr-Au

Gold Coated Soft Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F 160 kHz
C 5 N/m
L 125 µm
HQ:NSC15/Cr-Au

HQ:NSC15/Cr-Au

Gold Coated Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F 325 kHz
C 40 N/m
L 125 µm
HQ:NSC16/Cr-Au

HQ:NSC16/Cr-Au

Tapping Mode AFM Probe with Gold Coated Long Cantilever
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 45 N/m
L 225 µm
HQ:CSC38/Cr-Au

HQ:CSC38/Cr-Au

AFM Probe with 3 Different Gold Coated Contact Mode Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
F 20 kHz
C 0.09 N/m
L 250 µm
F 10 kHz
C 0.03 N/m
L 350 µm
F 14 kHz
C 0.05 N/m
L 300 µm
Tap150GB-G

Tap150GB-G

Gold Coated Soft Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F 150 kHz
C 5 N/m
L 125 µm
biosphere B20-NCH

biosphere B20-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
biosphere B20-FM

biosphere B20-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
biosphere B20-CONT

biosphere B20-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
biosphere B30-NCH

biosphere B30-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B30-FM

biosphere B30-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B30-CONT

biosphere B30-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
biosphere B40-NCH

biosphere B40-NCH

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 330 kHz
C 40 N/m
L 125 µm
New
biosphere B40-FM

biosphere B40-FM

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
New
biosphere B40-CONT

biosphere B40-CONT

Pre-calibrated EBD nanoindentation AFM probe
Coating: Reflex Gold
Tip Shape: Sphere,EBD
AFM Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
6