Non-Contact / Soft Tapping Mode AFM Probes

Soft samples in air or vacuum
59 results matching your criteria
PPP-FMAuD

PPP-FMAuD

Gold Coated Force Modulation AFM Probe
Coating: Reflex Gold
Tip Shape: Standard
AFM Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
HQ:NSC14/Cr-Au BS

HQ:NSC14/Cr-Au BS

Gold Coated Soft Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F 160 kHz
C 5 N/m
L 125 µm
top value
HQ:NSC18/Cr-Au BS

HQ:NSC18/Cr-Au BS

Gold Coated Force Modulation AFM Probe
Coating: Reflex Gold
Tip Shape: Rotated
AFM Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
Tap150GD-G

Tap150GD-G

Gold Coated Soft Tapping Mode Probe
Coating: Reflex Chromium/Gold
Tip Shape: Rotated
AFM Cantilever:
F 150 kHz
C 5 N/m
L 125 µm
New
biotool cell

biotool cell

EBD carbon whisker with 25 nm radius on soft cantilever
Coating: Reflex Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F 50 kHz
C 0.1 N/m
L 60 µm
qp-BioT

qp-BioT

uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 2 different triangular cantilevers

Coating: Reflex Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 2
F 50 kHz
C 0.3 N/m
L 100 µm
F 20 kHz
C 0.08 N/m
L 200 µm
HQ:NSC35/Cr-Au BS

HQ:NSC35/Cr-Au BS

AFM Probe with 3 Different Gold Coated Tapping Mode Cantilevers
Coating: Reflex Gold
Tip Shape: Rotated
AFM Cantilevers: 3
F 205 kHz
C 8.9 N/m
L 110 µm
F 300 kHz
C 16 N/m
L 90 µm
F 150 kHz
C 5.4 N/m
L 130 µm
Mix and Match Box

Mix and Match Box

Mixed box: up to 400 MikroMasch AFM probes
Coating: various
Tip Shape: various
HQ:XSC11/Al BS

HQ:XSC11/Al BS

AFM Probe with 4 Different Cantilevers for Various Applications
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilevers: 4
F 15 kHz
C 0.2 N/m
L 500 µm
F 80 kHz
C 2.7 N/m
L 210 µm
F 155 kHz
C 7 N/m
L 150 µm
F 350 kHz
C 42 N/m
L 100 µm
HQ:NSC19/Al BS

HQ:NSC19/Al BS

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F 65 kHz
C 0.5 N/m
L 125 µm
All-In-One-Al

All-In-One-Al

AFM Probe with 4 Different Cantilevers for Various Applications
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilevers: 4
F 15 kHz
C 0.2 N/m
L 500 µm
F 80 kHz
C 2.7 N/m
L 210 µm
F 150 kHz
C 7.4 N/m
L 150 µm
F 350 kHz
C 40 N/m
L 100 µm
top value
240AC-NG

240AC-NG

Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflex Gold
Tip Shape: OPUS
AFM Cantilever:
F 70 kHz
C 2 N/m
L 240 µm
best bang for your buck
Multi75GD-G

Multi75GD-G

Gold Coated Force Modulation AFM Probe
Coating: Reflex Gold
Tip Shape: Rotated
AFM Cantilever:
F 75 kHz
C 3 N/m
L 225 µm
New
qp-BioAC-CI

qp-BioAC-CI

uniqprobe™ BioAC with Rounded Tips for Cell Imaging
Coating: Reflex Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 3
F 90 kHz
C 0.3 N/m
L 40 µm
F 50 kHz
C 0.1 N/m
L 60 µm
F 30 kHz
C 0.06 N/m
L 80 µm
top value
3XC-NA

3XC-NA

AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM  Tips at the Very End of the AFM Cantilevers

Coating: Reflex Aluminum
Tip Shape: OPUS
AFM Cantilevers: 3
F 17 kHz
C 0.3 N/m
L 500 µm
F 150 kHz
C 9 N/m
L 175 µm
F 75 kHz
C 2.5 N/m
L 240 µm
New
biotool cell XXL

biotool cell XXL

Extralong 15 um EBD carbon whisker with 25 nm radius on soft cantilever
Coating: Reflex Gold
Tip Shape: EBD,Cone Shaped
AFM Cantilever:
F 50 kHz
C 0.1 N/m
L 60 µm
FESP

FESP

Standard Force Modulation AFM Probe

Coating: none
Tip Shape: Standard
AFM Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
HQ:NSC36/Al BS

HQ:NSC36/Al BS

AFM Probe with 3 Different Force Modulation Mode Cantilevers
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
F 90 kHz
C 1 N/m
L 110 µm
F 130 kHz
C 2 N/m
L 90 µm
F 65 kHz
C 0.6 N/m
L 130 µm
240AC-NN

240AC-NN

Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: none
Tip Shape: OPUS
AFM Cantilever:
F 70 kHz
C 2 N/m
L 240 µm
Tap150-G

Tap150-G

Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F 150 kHz
C 5 N/m
L 125 µm
3