Force Modulation AFM Cantilevers

89 results matching your criteria
ATEC-FM

ATEC-FM

Force Modulation AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
Cantilever:
F 85 kHz
C 2.8 N/m
L 240 µm
best of the best
PPP-FMR

PPP-FMR

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2 N/m
L 225 µm
ARROW-FMR

ARROW-FMR

Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: Arrow
Cantilever:
F 75 kHz
C 2.8 N/m
L 240 µm
the industry standard
FMR

FMR

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
top value
HQ:NSC18/Al BS

HQ:NSC18/Al BS

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
top value
240AC-NA

240AC-NA

Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: OPUS
Cantilever:
F 70 kHz
C 2 N/m
L 240 µm
best bang for your buck
Multi75Al-G

Multi75Al-G

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 3 N/m
L 225 µm
OLTESPA

OLTESPA

Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflex Aluminum
Tip Shape: OPUS
Cantilever:
F 70 kHz
C 2 N/m
L 240 µm
SSS-FMR

SSS-FMR

SuperSharp, Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Supersharp
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
DT-FMR

DT-FMR

Diamond Coated Force Modulation AFM Probe
Coating: Diamond
Tip Shape: Standard
Cantilever:
F 105 kHz
C 6.2 N/m
L 225 µm
NW-DT-FMR

NW-DT-FMR

Diamond Coated Force Modulation AFM Probe
Coating: Diamond
Tip Shape: Standard
Cantilever:
F 105 kHz
C 6.2 N/m
L 225 µm
Multi75DLC

Multi75DLC

Diamond-Like-Carbon Coated Force Modulation AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 3 N/m
L 225 µm
PPP-RT-FMR

PPP-RT-FMR

Standard Force Modulation AFM Probe
Coating: Reflex Aluminum
Tip Shape: Rotated
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
Special Developments

Special Developments

Download a List of Non-Standard, Special AFM Probes and More

Coating: various
Tip Shape: various
PPP-QFMR

PPP-QFMR

Force Modulation AFM Probe, for UHV Conditions
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
best of the best
PPP-LFMR

PPP-LFMR

Standard Lateral Force Mode AFM Probes
Coating: Reflex Aluminum
Tip Shape: Standard
Cantilever:
F 23 kHz
C 0.2 N/m
L 225 µm
best of the best
CDT-FMR

CDT-FMR

Diamond Coated, Conductive Force Modulation AFM Probe
Coating: Diamond,Conductive Diamond
Tip Shape: Standard
Cantilever:
F 105 kHz
C 6.2 N/m
L 225 µm
best of the best
PPP-EFM

PPP-EFM

Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
ATEC-EFM

ATEC-EFM

Electrical, Force Modulation AFM Probe with REAL Tip Visibility
Coating: Electrically Conductive
Tip Shape: Visible
Cantilever:
F 85 kHz
C 2.8 N/m
L 240 µm
the industry standard
NW-CDT-FMR

NW-CDT-FMR

Diamond Coated, Conductive Force Modulation AFM Probe

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
Cantilever:
F 105 kHz
C 6.2 N/m
L 225 µm
5