3.4 mm x 1.6 mm AFM Support Chips

AFM probes with 3.4 mm x 1.6 mm support chips
398 results matching your criteria
best of the best
PPP-NCSTR

PPP-NCSTR

Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
best of the best
PPP-NCHR

PPP-NCHR

Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
ATEC-NC

ATEC-NC

Tapping Mode AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
AFM Cantilever:
F
335 kHz
C
45 N/m
L
160 µm
New
PPP-NCR

PPP-NCR

Standard Tapping Mode AFM Probe with AC160 mechanical properties
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
300 kHz
C
26 N/m
L
125 µm
the industry standard
NCHR

NCHR

Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
TESPA

TESPA

Standard Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
ARROW-NCR

ARROW-NCR

Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflective Aluminum
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
top value
HQ:NSC15/Al BS

HQ:NSC15/Al BS

Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
top value
160AC-NA

160AC-NA

Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
best bang for your buck
Tap300Al-G

Tap300Al-G

Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
OTESPA

OTESPA

Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
PPP-NCLR

PPP-NCLR

Tapping Mode AFM Probe, Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCLR

NCLR

Tapping Mode AFM Probe, Long Cantilever
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
HQ:NSC16/Al BS

HQ:NSC16/Al BS

Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
Tap190Al-G

Tap190Al-G

Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
EBD-NCH

EBD-NCH

Universal EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating: none
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
best of the best
PPP-QNCHR

PPP-QNCHR

Tapping Mode AFM Probe, for UHV Conditions
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-RT-NCHR

PPP-RT-NCHR

Standard Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard
NCSTR

NCSTR

Soft Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
top value
HQ:NSC14/Al BS

HQ:NSC14/Al BS

Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
20