3 AFM Cantilevers on One Side of the AFM Probe

AFM probes with three AFM cantilevers on one side of the holder chip
Sort by:
40 results
HQ:NSC36/Pt
HQ:NSC36/Pt
AFM Probe with 3 Different Electrical, Force Modulation Mode AFM Cantilevers
Coating: Electrically Conductive
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:CSC37/Pt
HQ:CSC37/Pt
AFM Probe with 3 Different Electrical, Contact Mode AFM Cantilevers
Coating: Electrically Conductive
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
HQ:NSC35/Cr-Au
HQ:NSC35/Cr-Au
AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/Cr-Au
HQ:NSC36/Cr-Au
AFM Probe with 3 Different Gold Coated Force Modulation Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
3XC-GG
3XC-GG
AFM Probe with 3 Different Gold Coated AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating: Gold Overall
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
HQ:CSC37/Cr-Au
HQ:CSC37/Cr-Au
AFM Probe with 3 Different Gold Coated Contact Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
HQ:CSC38/Cr-Au
HQ:CSC38/Cr-Au
AFM Probe with 3 Different Gold Coated Contact Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
HQ:NSC35/tipless/No Al
HQ:NSC35/tipless/No Al
Tipless AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/tipless/No Al
HQ:NSC36/tipless/No Al
Tipless AFM Probe with 3 Different Force Modulation AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:CSC37/tipless/No Al
HQ:CSC37/tipless/No Al
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
top value
HQ:CSC38/tipless/No Al
HQ:CSC38/tipless/No Al
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
HQ:NSC35/tipless/Cr-Au
HQ:NSC35/tipless/Cr-Au
Tipless AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/tipless/Cr-Au
HQ:NSC36/tipless/Cr-Au
Tipless AFM Probe with 3 Different Gold Coated Force Modulation AFM Cantilevers
Coating: Gold Overall
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:CSC37/tipless/Cr-Au
HQ:CSC37/tipless/Cr-Au
Tipless AFM Probe with 3 Different Gold Coated Contact Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
HQ:CSC38/tipless/Cr-Au
HQ:CSC38/tipless/Cr-Au
Tipless AFM Probe with 3 Different Gold Coated Contact Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
HQ:NSC35/tipless/Al BS
HQ:NSC35/tipless/Al BS
Tipless AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/tipless/Al BS
HQ:NSC36/tipless/Al BS
Tipless AFM Probe with 3 Different Force Modulation AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:CSC37/tipless/Al BS
HQ:CSC37/tipless/Al BS
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
HQ:CSC38/tipless/Al BS
HQ:CSC38/tipless/Al BS
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
NANOSENSORS™ Special Developments List (SDL)
NANOSENSORS™ Special Developments List (SDL)
Special AFM Probes etc. Showcasing NANOSENSORS™ Expertise
Coating: various
Tip Shape: various
2