1 Single AFM Cantilever per AFM Probe

AFM probes with one single AFM cantilever
Sort by:
340 results
DDESP
DDESP

Diamond Coated, Conductive Tapping Mode AFM Probe

Coating: Diamond
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
DDESP-FM
DDESP-FM

Diamond Coated, Conductive Force Modulation AFM Probe

Coating: Diamond
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
OSCM-PT
OSCM-PT
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
PPP-NCSTAuD
PPP-NCSTAuD
Gold Coated Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-FMAuD
PPP-FMAuD
Gold Coated Force Modulation AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ARROW-UHFAuD
ARROW-UHFAuD

Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever

Coating: Reflective Gold
Tip Shape: Arrow
AFM Cantilever:
F
2000 kHz
C
x
L
35 µm
USC-F1.2-k0.15
USC-F1.2-k0.15
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1200 kHz
C
0.15 N/m
L
7 µm
HQ:NSC14/Cr-Au BS
HQ:NSC14/Cr-Au BS
Gold Coated Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
top value
HQ:NSC18/Cr-Au BS
HQ:NSC18/Cr-Au BS
Gold Coated Force Modulation AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
160AC-NG
160AC-NG
Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
Tap150GD-G
Tap150GD-G
Gold Coated Soft Tapping Mode Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
New
biotool cell
biotool cell
EBD carbon whisker with 25 nm radius on soft AFM cantilever
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm
best bang for your buck
Multi75GD-G
Multi75GD-G
Gold Coated Force Modulation AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
PPP-NCLAuD
PPP-NCLAuD
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
best of the best
qp-HBC
qp-HBC
uniqprobe™ - HeartBeat Cantilever for ScanAsyst®** and Peak Force Tapping™**
Coating: Reflective Aluminum
Tip Shape: Circular symmetric
AFM Cantilever:
F
60 kHz
C
0.5 N/m
L
115 µm
PPP-CONTSCR
PPP-CONTSCR
Contact Mode AFM Probe with Short AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
PPP-RT-CONTR
PPP-RT-CONTR
Standard Contact Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
USC-F0.3-k0.3
USC-F0.3-k0.3
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
300 kHz
C
0.3 N/m
L
20 µm
USC-F5-k30
USC-F5-k30
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
5000 kHz
C
30 N/m
L
10 µm
New
biotool high resolution
biotool high resolution
EBD carbon AFM whisker with 2 nm radius on soft AFM cantilever
Coating: Reflective Gold
Tip Shape: EBD,Cone Shaped,Supersharp
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm
17