3.4 mm x 1.6 mm AFM Support Chips

AFM probes with 3.4 mm x 1.6 mm support chips
Sort by:
LTESP
LTESP

Tapping Mode AFM Probe, Long Cantilever

Coating: none
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCL
NCL
Tapping Mode AFM Probe, Long Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
HQ:NSC15/No Al
HQ:NSC15/No Al
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
HQ:NSC16/No Al
HQ:NSC16/No Al
Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
top value
3XC-NA
3XC-NA

AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM  Tips at the Very End of the AFM Cantilevers

Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
160AC-NN
160AC-NN
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
Tap300-G
Tap300-G
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
Tap190-G
Tap190-G
Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
New
biotool cell XXL
biotool cell XXL
Extralong 15 um EBD carbon whisker with 25 nm radius on soft AFM cantilever
Coating: Reflective Gold
Tip Shape: EBD,Cone Shaped
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm
FESP
FESP

Standard Force Modulation AFM Probe

Coating: none
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC36/Al BS
HQ:NSC36/Al BS
AFM Probe with 3 Different Force Modulation Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
240AC-NN
240AC-NN
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
Tap150-G
Tap150-G
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
PPP-FM
PPP-FM
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
FM
FM
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ARROW-FM
ARROW-FM
Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: none
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm
HQ:NSC14/No Al
HQ:NSC14/No Al
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
HQ:NSC18/No Al
HQ:NSC18/No Al
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC19/No Al
HQ:NSC19/No Al
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
HQ:NSC35/No Al
HQ:NSC35/No Al
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: none
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
21