3.4 mm x 1.6 mm AFM Support Chips

AFM probes with 3.4 mm x 1.6 mm support chips
Sort by:
All-In-One-Al
All-In-One-Al
AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
top value
240AC-NG
240AC-NG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
HQ:NSC15/Cr-Au BS
HQ:NSC15/Cr-Au BS
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
HQ:NSC16/Cr-Au BS
HQ:NSC16/Cr-Au BS
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
Tap300GD-G
Tap300GD-G
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
Tap190GD-G
Tap190GD-G
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
PPP-CONTSC
PPP-CONTSC
Contact Mode AFM Probe with Short AFM Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
best of the best
PPP-MFMR
PPP-MFMR
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
SSS-MFMR
SSS-MFMR
SuperSharp, Hard Magnetic, Low Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
the industry standard
MFMR
MFMR
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
sale
S-MFMR
S-MFMR
Soft Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
HQ:NSC18/Co-Cr/Al BS
HQ:NSC18/Co-Cr/Al BS
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC36/Co-Cr/Al BS
HQ:NSC36/Co-Cr/Al BS
Hard Magnetic, Medium Momentum MFM AFM Probe with 3 Different AFM Cantilevers
Coating: Magnetic
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
60 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
top value
240AC-MA
240AC-MA
Hard Magnetic, Medium Momentum AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Magnetic
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best bang for your buck
MagneticMulti75-G
MagneticMulti75-G
Hard Magnetic, Medium Momentum AFM Probe
Coating: Magnetic
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
PPP-NCH
PPP-NCH
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-NCL
PPP-NCL
Tapping Mode AFM Probe, Long AFM Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCH
NCH
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
TESP
TESP

Standard Tapping Mode AFM Probe

Coating: none
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
ARROW-NC
ARROW-NC
Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: none
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
21