Non-Contact / Tapping Mode AFM Probes

General dynamic mode measurements
Sort by:
83 results
200AC-NA
200AC-NA
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
135 kHz
C
9 N/m
L
200 µm
best bang for your buck
Tap150Al-G
Tap150Al-G
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
PPP-NCST
PPP-NCST
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
NCST
NCST
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-NCHAuD
PPP-NCHAuD
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
best of the best
qp-BioAC
qp-BioAC
uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 3 different AFM cantilevers
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 3
1
2
3
F
90 kHz
50 kHz
30 kHz
C
0.3 N/m
0.1 N/m
0.06 N/m
L
40 µm
60 µm
80 µm
PPP-NCSTAuD
PPP-NCSTAuD
Gold Coated Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
ARROW-UHFAuD
ARROW-UHFAuD

Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever

Coating: Reflective Gold
Tip Shape: Arrow
AFM Cantilever:
F
2000 kHz
C
x
L
35 µm
USC-F1.2-k0.15
USC-F1.2-k0.15
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1200 kHz
C
0.15 N/m
L
7 µm
HQ:NSC14/Cr-Au BS
HQ:NSC14/Cr-Au BS
Gold Coated Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
Mix and Match Box
Mix and Match Box
Mixed box: up to 400 MikroMasch AFM probes
Coating: various
Tip Shape: various
160AC-NG
160AC-NG
Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
Tap150GD-G
Tap150GD-G
Gold Coated Soft Tapping Mode Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
The Standard SiNi probe
PNP-TR
PNP-TR
Silicon Nitride AFM Probe
Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
qp-BioT
qp-BioT
uniqprobe™ - uniform quality SPM probe for non-contact/tapping mode/contact mode with 2 different triangular AFM cantilevers
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilevers: 2
1
2
F
50 kHz
20 kHz
C
0.3 N/m
0.08 N/m
L
100 µm
200 µm
PPP-NCLAuD
PPP-NCLAuD
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
USC-F0.3-k0.3
USC-F0.3-k0.3
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
300 kHz
C
0.3 N/m
L
20 µm
USC-F5-k30
USC-F5-k30
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
5000 kHz
C
30 N/m
L
10 µm
PNP-DB
PNP-DB
Silicon Nitride AFM Probe
Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.48 N/m
0.06 N/m
L
100 µm
200 µm
HQ:NSC35/Cr-Au BS
HQ:NSC35/Cr-Au BS
AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
5