Silicon AFM Cantilevers

AFM probes with silicon AFM cantilevers
368 results matching your criteria
HQ:NSC35/Al BS

HQ:NSC35/Al BS

AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
200AC-NA

200AC-NA

Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
135 kHz
C
9 N/m
L
200 µm
best bang for your buck
Tap150Al-G

Tap150Al-G

Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
PPP-NCST

PPP-NCST

Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
NCST

NCST

Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
ATEC-FM

ATEC-FM

Force Modulation AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm
best of the best
PPP-FMR

PPP-FMR

Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ARROW-FMR

ARROW-FMR

Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflective Aluminum
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm
the industry standard
FMR

FMR

Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
HQ:NSC18/Al BS

HQ:NSC18/Al BS

Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
Mix and Match Box

Mix and Match Box

Mixed box: up to 400 MikroMasch AFM probes
Coating: various
Tip Shape: various
top value
240AC-NA

240AC-NA

Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best bang for your buck
Multi75Al-G

Multi75Al-G

Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
OLTESPA

OLTESPA

Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best of the best
SSS-NCHR

SSS-NCHR

SuperSharp, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Supersharp
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
SSS-NCLR

SSS-NCLR

SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
SSS-FMR

SSS-FMR

SuperSharp, Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
SSS-NCH

SSS-NCH

SuperSharp, Tapping Mode AFM Probe
Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard
NW-SSS-NCH

NW-SSS-NCH

SuperSharp, Tapping Mode AFM Probe
Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
TESP-SS

TESP-SS

SuperSharp, Tapping Mode AFM Probe

Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
19