Long Tapping Mode AFM Cantilevers

AFM probes with long tapping mode AFM cantilevers
33 results matching your criteria
PPP-NCLR

PPP-NCLR

Tapping Mode AFM Probe, Long AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
NCLR

NCLR

Tapping Mode AFM Probe, Long Cantilever
Coating: Reflex Aluminum
Tip Shape: Standard
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
HQ:NSC16/Al BS

HQ:NSC16/Al BS

Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 45 N/m
L 225 µm
Tap190Al-G

Tap190Al-G

Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
200AC-NA

200AC-NA

Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: OPUS
AFM Cantilever:
F 135 kHz
C 9 N/m
L 200 µm
SSS-NCLR

SSS-NCLR

SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: Supersharp
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
DT-NCLR

DT-NCLR

Diamond Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Diamond
Tip Shape: Standard
AFM Cantilever:
F 210 kHz
C 72 N/m
L 225 µm
NW-DT-NCLR

NW-DT-NCLR

Diamond Coated Tapping Mode AFM Probe with Long Cantilever
Coating: Diamond
Tip Shape: Standard
AFM Cantilever:
F 210 kHz
C 72 N/m
L 225 µm
PPP-NCLAuD

PPP-NCLAuD

Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflex Gold
Tip Shape: Standard
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
Tap190GD-G

Tap190GD-G

Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflex Gold
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
PPP-NCL

PPP-NCL

Tapping Mode AFM Probe, Long AFM Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
LTESP

LTESP

Tapping Mode AFM Probe, Long Cantilever

Coating: none
Tip Shape: Standard
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
NCL

NCL

Tapping Mode AFM Probe, Long Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
HQ:NSC16/No Al

HQ:NSC16/No Al

Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 45 N/m
L 225 µm
Tap190-G

Tap190-G

Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
SSS-NCL

SSS-NCL

SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
HQ:NSC16/Hard/Al BS

HQ:NSC16/Hard/Al BS

Long Scanning, DLC Hardened Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 45 N/m
L 225 µm
Tap190DLC

Tap190DLC

Diamond-Like-Carbon Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
AR5-NCLR

AR5-NCLR

High-Aspect-Ratio, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflex Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
NW-AR5-NCLR

NW-AR5-NCLR

High-Aspect-Ratio, Tapping Mode AFM Probe with Long Cantilever
Coating: Reflex Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
2