Platinum/Iridium Coated AFM Tips

AFM probes with platinum/iridium coated AFM tips
19 results matching your criteria
best of the best
PPP-EFM

PPP-EFM

Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ATEC-EFM

ATEC-EFM

Electrical, Force Modulation AFM Probe with REAL Tip Visibility
Coating: Electrically Conductive
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm
ARROW-EFM

ARROW-EFM

Electrical, Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm
the industry standard
EFM

EFM

Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
PPP-NCHPt

PPP-NCHPt

Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
ATEC-NCPt

ATEC-NCPt

Electrical, Tapping Mode AFM Probe with REAL Tip Visibility
Coating: Electrically Conductive
Tip Shape: Visible
AFM Cantilever:
F
335 kHz
C
45 N/m
L
160 µm
PPP-NCSTPt

PPP-NCSTPt

Electrical, Soft Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-NCLPt

PPP-NCLPt

Electrical, Tapping Mode AFM Probe with a Long AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCHPt

NCHPt

Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
ARROW-NCPt

ARROW-NCPt

Electrical, Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
NCLPt

NCLPt

Electrical, Tapping Mode AFM Probe with a Long Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
PPP-CONTPt

PPP-CONTPt

Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
PPP-CONTSCPt

PPP-CONTSCPt

Electrical, Contact Mode AFM Probe with Short AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
ATEC-CONTPt

ATEC-CONTPt

Electrical, Contact Mode AFM Probe with REAL Tip Visibility
Coating: Electrically Conductive
Tip Shape: Visible
AFM Cantilever:
F
15 kHz
C
0.2 N/m
L
450 µm
ARROW-CONTPt

ARROW-CONTPt

Electrical, Contact Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
AFM Cantilever:
F
14 kHz
C
0.2 N/m
L
450 µm
CONTPt

CONTPt

Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
SCM-PIC

SCM-PIC

Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
SCM-PIT

SCM-PIT

Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
NANOSENSORS™ Special Developments List (SDL)

NANOSENSORS™ Special Developments List (SDL)

Special AFM Probes etc. Showcasing NANOSENSORS™ Expertise
Coating: various
Tip Shape: various
1