Platinum/Iridium Coated AFM Tips

19 results matching your criteria
PPP-EFM

PPP-EFM

Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
ATEC-EFM

ATEC-EFM

Electrical, Force Modulation AFM Probe with REAL Tip Visibility
Coating: Electrically Conductive
Tip Shape: Visible
Cantilever:
F 85 kHz
C 2.8 N/m
L 240 µm
ARROW-EFM

ARROW-EFM

Electrical, Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
Cantilever:
F 75 kHz
C 2.8 N/m
L 240 µm
EFM

EFM

Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
PPP-NCHPt

PPP-NCHPt

Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 330 kHz
C 42 N/m
L 125 µm
ATEC-NCPt

ATEC-NCPt

Electrical, Tapping Mode AFM Probe with REAL Tip Visibility
Coating: Electrically Conductive
Tip Shape: Visible
Cantilever:
F 335 kHz
C 45 N/m
L 160 µm
PPP-NCSTPt

PPP-NCSTPt

Electrical, Soft Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 160 kHz
C 7.4 N/m
L 150 µm
Special Developments

Special Developments

Not available in the standard scope of products
Coating: various
Tip Shape: various
PPP-NCLPt

PPP-NCLPt

Electrical, Tapping Mode AFM Probe with a Long Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
NCHPt

NCHPt

Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 320 kHz
C 42 N/m
L 125 µm
ARROW-NCPt

ARROW-NCPt

Electrical, Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
Cantilever:
F 285 kHz
C 42 N/m
L 160 µm
PPP-CONTPt

PPP-CONTPt

Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
PPP-CONTSCPt

PPP-CONTSCPt

Electrical, Contact Mode AFM Probe with Short Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 25 kHz
C 0.2 N/m
L 225 µm
ATEC-CONTPt

ATEC-CONTPt

Electrical, Contact Mode AFM Probe with REAL Tip Visibility
Coating: Electrically Conductive
Tip Shape: Visible
Cantilever:
F 15 kHz
C 0.2 N/m
L 450 µm
CONTPt

CONTPt

Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
ARROW-CONTPt

ARROW-CONTPt

Electrical, Contact Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
Cantilever:
F 14 kHz
C 0.2 N/m
L 450 µm
SCM-PIC

SCM-PIC

Electrical, Contact Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 13 kHz
C 0.2 N/m
L 450 µm
SCM-PIT

SCM-PIT

Electrical, Force Modulation AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 75 kHz
C 2.8 N/m
L 225 µm
NCLPt

NCLPt

Electrical, Tapping Mode AFM Probe with a Long Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
Cantilever:
F 190 kHz
C 48 N/m
L 225 µm
1