Silicon AFM Tips

AFM probes with silicon AFM tips
276 results matching your criteria
PPP-FMAuD

PPP-FMAuD

Gold Coated Force Modulation AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ARROW-UHFAuD

ARROW-UHFAuD

Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever

Coating: Reflective Gold
Tip Shape: Arrow
AFM Cantilever:
F
2000 kHz
C
x
L
35 µm
HQ:NSC14/Cr-Au BS

HQ:NSC14/Cr-Au BS

Gold Coated Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
top value
HQ:NSC18/Cr-Au BS

HQ:NSC18/Cr-Au BS

Gold Coated Force Modulation AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
160AC-NG

160AC-NG

Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: OPUS
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
Tap150GD-G

Tap150GD-G

Gold Coated Soft Tapping Mode Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
PPP-NCLAuD

PPP-NCLAuD

Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
PPP-CONTSCR

PPP-CONTSCR

Contact Mode AFM Probe with Short AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
PPP-RT-CONTR

PPP-RT-CONTR

Standard Contact Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
HQ:NSC35/Cr-Au BS

HQ:NSC35/Cr-Au BS

AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
55AC-NN

55AC-NN

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: none
Tip Shape: OPUS
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value
55AC-NA

55AC-NA

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Aluminum
Tip Shape: OPUS
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
55AC-NG

55AC-NG

Gold Coated Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold
Tip Shape: OPUS
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
HQ:XSC11/Al BS

HQ:XSC11/Al BS

AFM Probe with 4 Different Cantilevers for Various Applications
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm
HQ:NSC36/Cr-Au BS

HQ:NSC36/Cr-Au BS

AFM Probe with 3 Different Gold Coated Force Modulation Mode AFM Cantilevers
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:NSC19/Al BS

HQ:NSC19/Al BS

Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
All-In-One-Al

All-In-One-Al

AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
top value
240AC-NG

240AC-NG

Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: OPUS
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
HQ:NSC15/Cr-Au BS

HQ:NSC15/Cr-Au BS

Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
New
HQ:NSC16/Cr-Au BS

HQ:NSC16/Cr-Au BS

Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
14