Back Side Aluminum Coated AFM Cantilevers

AFM probes with back side aluminum coated AFM cantilevers
Sort by:
133 results
HQ:NSC36/Hard/Al BS
HQ:NSC36/Hard/Al BS
AFM Probe with 3 Different Long Scanning, DLC Hardened Force Modulation Mode AFM Cantilevers
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:XSC11/Hard/Al BS
HQ:XSC11/Hard/Al BS
AFM Probe with 4 Different Long Scanning, DLC Hardened Cantilevers for Various Applications
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm
Tap150DLC
Tap150DLC
Diamond-Like-Carbon Coated Soft Tapping Mode AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
Tap190DLC
Tap190DLC
Diamond-Like-Carbon Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
DT-CONTR
DT-CONTR
Diamond Coated Contact Mode AFM Probe
Coating: Diamond
Tip Shape: Standard
AFM Cantilever:
F
20 kHz
C
0.5 N/m
L
450 µm
HQ:CSC17/Hard/Al BS
HQ:CSC17/Hard/Al BS
Long Scanning, DLC Hardened Contact Mode AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.18 N/m
L
450 µm
ContDLC
ContDLC
Diamond-Like-Carbon Coated Contact Mode AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
best of the best
AR10T-NCHR
AR10T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5T-NCHR
AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard
NW-AR5T-NCHR
NW-AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
TESPA-HAR
TESPA-HAR

High-Aspect-Ratio, Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
the industry standard
ARROW-UHF
ARROW-UHF
Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflective Aluminum
Tip Shape: Arrow
AFM Cantilever:
F
2000 kHz
C
x
L
35 µm
ESPA
ESPA

Standard Contact Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
CONTSCR
CONTSCR
Contact Mode AFM Probe with Short Cantilever
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
HQ:CSC37/Al BS
HQ:CSC37/Al BS
AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
HQ:CSC38/Al BS
HQ:CSC38/Al BS
AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
AR10-NCHR
AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCHR
AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
NW-AR10-NCHR
NW-AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
NW-AR5-NCHR
NW-AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
7