Trapezoidal Cross Section AFM Cantilevers (tip on narrow flank)

Sort by:
328 results
HQ:CSC38/No Al
HQ:CSC38/No Al
AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: none
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
PPP-BSI
PPP-BSI
Soft Contact AFM Probe for Biological Applications
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
28 kHz
C
0.1 N/m
L
225 µm
EBD-AR15T
EBD-AR15T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
AR10-NCHR
AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCHR
AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCH
AR5-NCH
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: none
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
NW-AR10-NCHR
NW-AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
NW-AR5-NCHR
NW-AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
AR5-NCLR
AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NW-AR5-NCLR
NW-AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long Cantilever
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
CDT-NCHR
CDT-NCHR
Diamond Coated, Conductive Tapping Mode AFM Probe
Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
CDT-NCLR
CDT-NCLR
Diamond Coated, Conductive Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm
NW-CDT-NCHR
NW-CDT-NCHR

Diamond Coated, Conductive Tapping Mode AFM Probe

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
NW-CDT-NCLR
NW-CDT-NCLR

Diamond Coated, Conductive Tapping Mode AFM Probe with Long Cantilever

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm
PPP-NCHPt
PPP-NCHPt
Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-NCSTPt
PPP-NCSTPt
Electrical, Soft Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-NCLPt
PPP-NCLPt
Electrical, Tapping Mode AFM Probe with a Long AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCHPt
NCHPt
Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
ARROW-NCPt
ARROW-NCPt
Electrical, Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
top value
HQ:DMD-XSC11
HQ:DMD-XSC11
AFM Probe with 4 Different Diamond Coated, Conductive Cantilevers for Various Applications
Coating: Conductive Diamond
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
18 kHz
110 kHz
210 kHz
450 kHz
C
0.5 N/m
6.5 N/m
18 N/m
95 N/m
L
500 µm
210 µm
150 µm
100 µm
17